Effects of eddy currents on selective spectral editing experiments at 3T. Issue 3 (22nd July 2017)
- Record Type:
- Journal Article
- Title:
- Effects of eddy currents on selective spectral editing experiments at 3T. Issue 3 (22nd July 2017)
- Main Title:
- Effects of eddy currents on selective spectral editing experiments at 3T
- Authors:
- Oeltzschner, Georg
Snoussi, Karim
Puts, Nicolaas A.
Mikkelsen, Mark
Harris, Ashley D.
Pradhan, Subechhya
Tsapkini, Kyrana
Schär, Michael
Barker, Peter B.
Edden, Richard A.E. - Abstract:
- Abstract : Purpose: To investigate frequency‐offset effects in edited magnetic resonance spectroscopy (MRS) experiments arising from B0 eddy currents. Materials and Methods: Macromolecule‐suppressed (MM‐suppressed) γ‐aminobutyric acid (GABA)‐edited experiments were performed at 3T. Saturation‐offset series of MEGA‐PRESS experiments were performed in phantoms, in order to investigate different aspects of the relationship between the effective editing frequencies and eddy currents associated with gradient pulses in the sequence. Difference integrals were quantified for each series, and the offset dependence of the integrals was analyzed to quantify the difference in frequency (Δf) between the actual vs. nominal expected saturation frequency. Results: Saturation‐offset N‐acetyl‐aspartate‐phantom experiments show that Δf varied with voxel orientation, ranging from 10.4 Hz (unrotated) to 6.4 Hz (45° rotation about the caudal–cranial axis) and 0.4 Hz (45° rotation about left–right axis), indicating that gradient‐related B0 eddy currents vary with crusher‐gradient orientation. Fixing the crusher‐gradient coordinate‐frame substantially reduced the orientation dependence of Δf (to ∼2 Hz). Water‐suppression crusher gradients also introduced a frequency offset, with Δf = 0.6 Hz ("excitation" water suppression), compared to 10.2 Hz (no water suppression). In vivo spectra showed a negative edited "GABA" signal, suggesting Δf on the order of 10 Hz; with fixed crusher‐gradientAbstract : Purpose: To investigate frequency‐offset effects in edited magnetic resonance spectroscopy (MRS) experiments arising from B0 eddy currents. Materials and Methods: Macromolecule‐suppressed (MM‐suppressed) γ‐aminobutyric acid (GABA)‐edited experiments were performed at 3T. Saturation‐offset series of MEGA‐PRESS experiments were performed in phantoms, in order to investigate different aspects of the relationship between the effective editing frequencies and eddy currents associated with gradient pulses in the sequence. Difference integrals were quantified for each series, and the offset dependence of the integrals was analyzed to quantify the difference in frequency (Δf) between the actual vs. nominal expected saturation frequency. Results: Saturation‐offset N‐acetyl‐aspartate‐phantom experiments show that Δf varied with voxel orientation, ranging from 10.4 Hz (unrotated) to 6.4 Hz (45° rotation about the caudal–cranial axis) and 0.4 Hz (45° rotation about left–right axis), indicating that gradient‐related B0 eddy currents vary with crusher‐gradient orientation. Fixing the crusher‐gradient coordinate‐frame substantially reduced the orientation dependence of Δf (to ∼2 Hz). Water‐suppression crusher gradients also introduced a frequency offset, with Δf = 0.6 Hz ("excitation" water suppression), compared to 10.2 Hz (no water suppression). In vivo spectra showed a negative edited "GABA" signal, suggesting Δf on the order of 10 Hz; with fixed crusher‐gradient coordinate‐frame, the expected positive edited "GABA" signal was observed. Conclusion: Eddy currents associated with pulsed field gradients may have a considerable impact on highly frequency‐selective spectral‐editing experiments, such as MM‐suppressed GABA editing at 3T. Careful selection of crusher gradient orientation may ameliorate these effects. Level of Evidence : 2 Technical Efficacy : Stage 1 J. Magn. Reson. Imaging 2018;47:673–681. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 47:Issue 3(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 47:Issue 3(2018)
- Issue Display:
- Volume 47, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2018-0047-0003-0000
- Page Start:
- 673
- Page End:
- 681
- Publication Date:
- 2017-07-22
- Subjects:
- edited MRS -- offset -- GABA -- macromolecules -- eddy currents -- MEGA‐PRESS
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25813 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5935.xml