All-Inside Meniscal Repair Devices Compared With Their Matched Inside-Out Vertical Mattress Suture Repair: Introducing 10, 000 and 100, 000 Loading Cycles. (September 2014)
- Record Type:
- Journal Article
- Title:
- All-Inside Meniscal Repair Devices Compared With Their Matched Inside-Out Vertical Mattress Suture Repair: Introducing 10, 000 and 100, 000 Loading Cycles. (September 2014)
- Main Title:
- All-Inside Meniscal Repair Devices Compared With Their Matched Inside-Out Vertical Mattress Suture Repair
- Authors:
- Rosso, Claudio
Müller, Sebastian
Buckland, Daniel M.
Schwenk, Tanja
Zimmermann, Simon
de Wild, Michael
Valderrabano, Victor - Abstract:
- Background: All-inside arthroscopic meniscal repairs are favored by most clinicians because of their lower complication rate and decreased morbidity compared with inside-out techniques. Until now, only 1000 cycles have been used for biomechanical testing. Hypothesis: All-inside meniscal repairs will show inferior biomechanical response to cyclic loading (up to 100, 000 cycles) and load-to-failure testing compared with inside-out suture controls. Study Design: Controlled laboratory study. Methods: Bucket-handle tears in 72 porcine menisci were repaired using the Omnispan and Fast-Fix 360 (all-inside devices) and Orthocord 2-0 and Ultrabraid 2-0 sutures (matched controls). Initial displacement, displacement after cyclic loading (100, 500, 1000, 2000, 5000, 10, 000, and 100, 000 cycles) between 5 and 20 N, ultimate load to failure, and mode of failure were recorded, as well as stiffness. Results: Initial displacement and displacement after cyclic loading were not different between the groups. The Omnispan repair demonstrated the highest load-to-failure force (mean ± SD, 151.3 ± 21.5 N) and was significantly stronger than all the other constructs (Orthocord 2-0, 105.5 ± 20.4 N; Ultrabraid 2-0, 93.4 ± 22.5 N; Fast-Fix 360, 76.6 ± 14.2 N) ( P < .0001 for all). The Orthocord vertical inside-out mattress repair was significantly stronger than the Fast-Fix 360 repair ( P = .003). The Omnispan (30.8 ± 3.5 N/mm) showed significantly higher stiffness compared with the Ultrabraid 2-0Background: All-inside arthroscopic meniscal repairs are favored by most clinicians because of their lower complication rate and decreased morbidity compared with inside-out techniques. Until now, only 1000 cycles have been used for biomechanical testing. Hypothesis: All-inside meniscal repairs will show inferior biomechanical response to cyclic loading (up to 100, 000 cycles) and load-to-failure testing compared with inside-out suture controls. Study Design: Controlled laboratory study. Methods: Bucket-handle tears in 72 porcine menisci were repaired using the Omnispan and Fast-Fix 360 (all-inside devices) and Orthocord 2-0 and Ultrabraid 2-0 sutures (matched controls). Initial displacement, displacement after cyclic loading (100, 500, 1000, 2000, 5000, 10, 000, and 100, 000 cycles) between 5 and 20 N, ultimate load to failure, and mode of failure were recorded, as well as stiffness. Results: Initial displacement and displacement after cyclic loading were not different between the groups. The Omnispan repair demonstrated the highest load-to-failure force (mean ± SD, 151.3 ± 21.5 N) and was significantly stronger than all the other constructs (Orthocord 2-0, 105.5 ± 20.4 N; Ultrabraid 2-0, 93.4 ± 22.5 N; Fast-Fix 360, 76.6 ± 14.2 N) ( P < .0001 for all). The Orthocord vertical inside-out mattress repair was significantly stronger than the Fast-Fix 360 repair ( P = .003). The Omnispan (30.8 ± 3.5 N/mm) showed significantly higher stiffness compared with the Ultrabraid 2-0 (22.9 ± 6.9 N/mm, P < .0001) and Fast-Fix 360 (23.7 ± 3.9 N/mm, P = .001). The predominant mode of failure was suture failure. Conclusion: All-inside meniscal devices show comparable biomechanical properties compared with inside-out suture repair in cyclic loading, even after 100, 000 cycles. Clinical Relevance: Eight to 10 weeks of rehabilitation might not pose a problem for all repairs in this worst-case scenario. … (more)
- Is Part Of:
- American journal of sports medicine. Volume 42:Number 9(2014:Sep.)
- Journal:
- American journal of sports medicine
- Issue:
- Volume 42:Number 9(2014:Sep.)
- Issue Display:
- Volume 42, Issue 9 (2014)
- Year:
- 2014
- Volume:
- 42
- Issue:
- 9
- Issue Sort Value:
- 2014-0042-0009-0000
- Page Start:
- 2226
- Page End:
- 2233
- Publication Date:
- 2014-09
- Subjects:
- meniscus -- repair -- biomechanics -- biomechanical testing -- all-inside -- Omnispan -- Fast-Fix 360 -- Ultrabraid -- Orthocord
Sports medicine -- Periodicals
Sports injuries -- Periodicals
Orthopedic surgery -- Periodicals
617.102705 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0363-5465 ↗
http://ajs.sagepub.com ↗
http://www.ajsm.org ↗
http://www.sagepub.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1177/0363546514538394 ↗
- Languages:
- English
- ISSNs:
- 0363-5465
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5930.xml