False negative single antigen bead assay: Is it always an effect of prozone?. Issue 2 (26th April 2017)
- Record Type:
- Journal Article
- Title:
- False negative single antigen bead assay: Is it always an effect of prozone?. Issue 2 (26th April 2017)
- Main Title:
- False negative single antigen bead assay: Is it always an effect of prozone?
- Authors:
- Jain, Dharmendra
Choudhuri, Jui
Chauhan, Rajni
Dorwal, Pranav
Sharma, Deepak
Tiwari, Aseem K.
Raina, Vimarsh - Abstract:
- Abstract : Background: Bead based flow cytometry and Luminex play a major role in identification of alloantibodies in renal transplant work‐up. Strong sensitization events may lead to prozone phenomenon that can affect single antigen bead (SAB) assay and result in false negativity. However, this can also be due to high titer of other blocking antibodies. While methods like, heat inactivation, C1 inhibitor, Ethylene diamine tetra‐acetic‐acid and Dithio threitol treatment can remove interfering antibodies of complement and IgM, these methods are not optimal if false negativity is due to prozone effect, which is high titer of antibodies alone. Methods: We hereby present a case of a highly sensitized renal transplant recipient with 64% panel reactive antibody positivity (PRA) and a subsequent negative SAB assay. This paradoxical finding hinted at SAB being a false negative result and serial dilutions were used to perform further tests. Results: Serum dilutions lead to positive flow based panel reactive antibody (PRA) and flow cytometry crossmatch (FCXM), with an increasing trend in FCXM. Conclusions: In highly sensitized patients serial dilution should be considered during a transplant work‐up to avoid missing any underlying antibodies. Serum dilution can be used as first option to circumvent prozone. Also, interference of other antibodies should not be labeled as prozone effect.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 32:Issue 2(2018)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 32:Issue 2(2018)
- Issue Display:
- Volume 32, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2018-0032-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-04-26
- Subjects:
- human leukocyte antigen -- panel reactive antibodies -- prozone effect -- renal transplant -- single antigen bead assay
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22237 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5919.xml