Concurrent validity and interrater reliability of a new smartphone application to assess 3D active cervical range of motion in patients with neck pain. (April 2018)
- Record Type:
- Journal Article
- Title:
- Concurrent validity and interrater reliability of a new smartphone application to assess 3D active cervical range of motion in patients with neck pain. (April 2018)
- Main Title:
- Concurrent validity and interrater reliability of a new smartphone application to assess 3D active cervical range of motion in patients with neck pain
- Authors:
- Stenneberg, Martijn S.
Busstra, Harm
Eskes, Michel
van Trijffel, Emiel
Cattrysse, Erik
Scholten-Peeters, Gwendolijne G.M.
de Bie, Rob A. - Abstract:
- Abstract: Background: There is a lack of valid, reliable, and feasible instruments for measuring planar active cervical range of motion (aCROM) and associated 3D coupling motions in patients with neck pain. Smartphones have advanced sensors and appear to be suitable for these measurements. Objectives: To estimate the concurrent validity and interrater reliability of a new iPhone application for assessing planar aCROM and associated 3D coupling motions in patients with neck pain, using an electromagnetic tracking device as a reference test. Design: Cross-sectional study. Methods: Two samples of neck pain patients were recruited; 30 patients for the validity study and 26 patients for the reliability study. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Cervical 3D coupling motions were analyzed by calculating the cross-correlation coefficients and ratio between the main motions and coupled motions for both instruments. Results: ICCs for concurrent validity and interrater reliability ranged from 0.90 to 0.99. The width of the 95% LoA ranged from about 5° for right lateral bending to 11° for total rotation. No significant differences were found between both devices for associated coupling motion analysis. Conclusions: The iPhone application appears to be a useful discriminative tool for the measurement of planar aCROM and associated couplingAbstract: Background: There is a lack of valid, reliable, and feasible instruments for measuring planar active cervical range of motion (aCROM) and associated 3D coupling motions in patients with neck pain. Smartphones have advanced sensors and appear to be suitable for these measurements. Objectives: To estimate the concurrent validity and interrater reliability of a new iPhone application for assessing planar aCROM and associated 3D coupling motions in patients with neck pain, using an electromagnetic tracking device as a reference test. Design: Cross-sectional study. Methods: Two samples of neck pain patients were recruited; 30 patients for the validity study and 26 patients for the reliability study. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Cervical 3D coupling motions were analyzed by calculating the cross-correlation coefficients and ratio between the main motions and coupled motions for both instruments. Results: ICCs for concurrent validity and interrater reliability ranged from 0.90 to 0.99. The width of the 95% LoA ranged from about 5° for right lateral bending to 11° for total rotation. No significant differences were found between both devices for associated coupling motion analysis. Conclusions: The iPhone application appears to be a useful discriminative tool for the measurement of planar aCROM and associated coupling motions in patients with neck pain. It fulfills the need for a valid, reliable, and feasible instrument in clinical practice and research. Therapists and researchers should consider measurement error when interpreting scores. Highlights: The iPhone is valid and reliable to measure cervical ROM in patients with neck pain. The iPhone is useful to measure cervical 3D coupling motions. Clinicians should consider the relatively large measurement error in practice. … (more)
- Is Part Of:
- Musculoskeletal science and practice. Volume 34(2018)
- Journal:
- Musculoskeletal science and practice
- Issue:
- Volume 34(2018)
- Issue Display:
- Volume 34, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 2018
- Issue Sort Value:
- 2018-0034-2018-0000
- Page Start:
- 59
- Page End:
- 65
- Publication Date:
- 2018-04
- Subjects:
- Active range of motion -- Assessment -- Nonspecific neck pain -- Reliability and validity -- Smartphone
Manipulation (Therapeutics) -- Periodicals
Physical therapy -- Periodicals
Neuromuscular diseases -- Treatment -- Periodicals
Musculoskeletal system -- Diseases -- Periodicals
Manipulation (Therapeutics)
Neuromuscular diseases -- Treatment
Physical therapy
Manipulation, Orthopedic
Musculoskeletal Diseases -- therapy
Neuromuscular Diseases -- therapy
Physical Therapy Modalities
Electronic journals
Periodicals
615.82 - Journal URLs:
- https://www.clinicalkey.com/#!/browse/journal/24687812/latest ↗
https://www.journals.elsevier.com/musculoskeletal-science-and-practice ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.msksp.2017.12.006 ↗
- Languages:
- English
- ISSNs:
- 2468-8630
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5986.535400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5882.xml