Systemic Evaluation of Vascular Dysfunction by High‐Resolution Sonography in an Nω‐Nitro‐l‐Arginine Methyl Ester Hydrochloride–Induced Mouse Model of Preeclampsia‐Like Symptoms. (15th September 2017)
- Record Type:
- Journal Article
- Title:
- Systemic Evaluation of Vascular Dysfunction by High‐Resolution Sonography in an Nω‐Nitro‐l‐Arginine Methyl Ester Hydrochloride–Induced Mouse Model of Preeclampsia‐Like Symptoms. (15th September 2017)
- Main Title:
- Systemic Evaluation of Vascular Dysfunction by High‐Resolution Sonography in an Nω‐Nitro‐l‐Arginine Methyl Ester Hydrochloride–Induced Mouse Model of Preeclampsia‐Like Symptoms
- Authors:
- Zhao, Ying
Yang, Ning
Li, Hanying
Cai, Wei
Zhang, Xin
Ma, Yongqiang
Niu, Xiulong
Yang, Guohong
Zhou, Xin
Li, Yuming - Abstract:
- Abstract : Objectives: The purpose of this study was to evaluate vascular function, including arterial resistance and endothelial function, by high‐resolution sonography in an N ω ‐nitro‐l ‐arginine methyl ester hydrochloride (l ‐NAME)‐induced mouse model of preeclampsia‐like symptoms. Methods: Pregnant mice were subcutaneously injected with a saline solution (control; n = 10) orl ‐NAME (n = 10) between the 7th and 18th days of gestation. The resistive index and pulsatility index (RI and PI, indicators of arterial resistance) of the uteroplacental, umbilical, femoral, and common carotid arteries and the flow‐mediated dilatation (index of endothelial function) of the femoral artery were measured by high‐frequency sonography in both groups. Results: We noted significant increases in the RI and PI of the uteroplacental and umbilical arteries and a decrease in the flow‐mediated dilatation of the femoral artery in thel ‐NAME group compared with the control group. We also found that the RI and PI of the uteroplacental and umbilical arteries were negatively correlated with fetal weight and crown‐rump length. The results of the multivariate analysis using a logistic regression model indicated that the flow‐mediated dilatation at 120 seconds was an independent diagnostic criterion for thel ‐NAME‐induced preeclampsia‐like model. A receiver operating characteristic analysis showed that flow‐mediated dilatation at 120 seconds had the greatest area under the curve of 0.934, with anAbstract : Objectives: The purpose of this study was to evaluate vascular function, including arterial resistance and endothelial function, by high‐resolution sonography in an N ω ‐nitro‐l ‐arginine methyl ester hydrochloride (l ‐NAME)‐induced mouse model of preeclampsia‐like symptoms. Methods: Pregnant mice were subcutaneously injected with a saline solution (control; n = 10) orl ‐NAME (n = 10) between the 7th and 18th days of gestation. The resistive index and pulsatility index (RI and PI, indicators of arterial resistance) of the uteroplacental, umbilical, femoral, and common carotid arteries and the flow‐mediated dilatation (index of endothelial function) of the femoral artery were measured by high‐frequency sonography in both groups. Results: We noted significant increases in the RI and PI of the uteroplacental and umbilical arteries and a decrease in the flow‐mediated dilatation of the femoral artery in thel ‐NAME group compared with the control group. We also found that the RI and PI of the uteroplacental and umbilical arteries were negatively correlated with fetal weight and crown‐rump length. The results of the multivariate analysis using a logistic regression model indicated that the flow‐mediated dilatation at 120 seconds was an independent diagnostic criterion for thel ‐NAME‐induced preeclampsia‐like model. A receiver operating characteristic analysis showed that flow‐mediated dilatation at 120 seconds had the greatest area under the curve of 0.934, with an optimal cutoff point of 11.1%, yielding sensitivity of 100% and specificity of 84.6%. Conclusions: The PI and RI of the fetomaternal vasculature can identify fetuses in "high‐risk" pregnancies, and flow‐mediated dilatation is a reliable indicator for predicting preeclampsia. Assessment of vascular function by high‐resolution sonography provides a useful platform for preeclampsia‐related basic research with high reproducibility. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 37:Number 3(2018)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 37:Number 3(2018)
- Issue Display:
- Volume 37, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 3
- Issue Sort Value:
- 2018-0037-0003-0000
- Page Start:
- 657
- Page End:
- 666
- Publication Date:
- 2017-09-15
- Subjects:
- animal studies -- Doppler (techniques/physics) -- flow‐mediated dilatation -- high‐frequency imaging -- high‐intensity focused ultrasound/sonoporation -- high‐resolution sonography -- obstetrics -- preeclampsia -- pulsatility index -- resistive index -- vascular dysfunction
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.14380 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5886.xml