The performance of T‐cell Xtend reagent in increasing blood storage times for interferon gamma release assays. Issue 2 (3rd July 2017)
- Record Type:
- Journal Article
- Title:
- The performance of T‐cell Xtend reagent in increasing blood storage times for interferon gamma release assays. Issue 2 (3rd July 2017)
- Main Title:
- The performance of T‐cell Xtend reagent in increasing blood storage times for interferon gamma release assays
- Authors:
- Li, Junlian
Liu, Yan
Ma, Liyamu
Gu, Libike
Wang, Quan
Xu, Miao
Ma, Ruiying
Zhang, Yali
Yang, Zhenping
Deng, Junjie
Yi, Xing - Abstract:
- Abstract : Background: T‐cell Xtend (TCX) was introduced to extend the blood storage time for T‐SPOT.TB test, a widely used commercial interferon gamma release assay (IGRA) for rapid in vitro tuberculosis. Methods: A total of 99 Uyghur suspected tuberculosis patients were recruited in this study. T‐SPOT.TB test was performed with fresh blood (controls), 36 hours delayed blood and delayed and TCX‐treated (at 36 hours) blood from each patient, respectively. Results: White blood cells and lymphocytes proportion in peripheral blood mononuclear cells s and spot‐forming cells in positive control wells decreased significantly in delayed blood samples when compared with controls, while this decrease was not detected in TCX‐treated group. In the 58 patients with paired T‐SPOT.TB results of three groups of samples, a higher positive rate was observed in TCX‐treated group than both in controls and untreated group (41.4% vs 37.9% and 25.9%). The concordance of T‐SPOT.TB results between the treated group and controls was 0.856, whereas the agreement between controls and untreated group was unsatisfactory (0.649). In the 23 elderly patients (>70 years old) with paired T‐SPOT.TB results of controls and TCX group, treated group showed a non‐significant trend toward higher positive rate than controls (43.5% vs 26.1%, P =.22). Meanwhile, TCX treatment reduced the risk of false negative T‐SPOT.TB results in the elderly population. Conclusion: Deterioration of blood sample caused by longAbstract : Background: T‐cell Xtend (TCX) was introduced to extend the blood storage time for T‐SPOT.TB test, a widely used commercial interferon gamma release assay (IGRA) for rapid in vitro tuberculosis. Methods: A total of 99 Uyghur suspected tuberculosis patients were recruited in this study. T‐SPOT.TB test was performed with fresh blood (controls), 36 hours delayed blood and delayed and TCX‐treated (at 36 hours) blood from each patient, respectively. Results: White blood cells and lymphocytes proportion in peripheral blood mononuclear cells s and spot‐forming cells in positive control wells decreased significantly in delayed blood samples when compared with controls, while this decrease was not detected in TCX‐treated group. In the 58 patients with paired T‐SPOT.TB results of three groups of samples, a higher positive rate was observed in TCX‐treated group than both in controls and untreated group (41.4% vs 37.9% and 25.9%). The concordance of T‐SPOT.TB results between the treated group and controls was 0.856, whereas the agreement between controls and untreated group was unsatisfactory (0.649). In the 23 elderly patients (>70 years old) with paired T‐SPOT.TB results of controls and TCX group, treated group showed a non‐significant trend toward higher positive rate than controls (43.5% vs 26.1%, P =.22). Meanwhile, TCX treatment reduced the risk of false negative T‐SPOT.TB results in the elderly population. Conclusion: Deterioration of blood sample caused by long storage time can be neutralized by TCX treatment. The results provide data for the utility of TCX in a novel population and in Asian region, and reveal the potential of TCX to improve the accuracy of T‐SPOT.TB test in elderly population. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 32:Issue 2(2018)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 32:Issue 2(2018)
- Issue Display:
- Volume 32, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2018-0032-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-07-03
- Subjects:
- elderly population -- interferon gamma release assays -- T‐cell Xtend -- T‐SPOT.TB assay -- Tuberculosis
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22253 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5903.xml