Micro‐instillation of fluorescein with an inoculation loop for ocular surface staining in dry eye syndrome. Issue 2 (25th October 2017)
- Record Type:
- Journal Article
- Title:
- Micro‐instillation of fluorescein with an inoculation loop for ocular surface staining in dry eye syndrome. Issue 2 (25th October 2017)
- Main Title:
- Micro‐instillation of fluorescein with an inoculation loop for ocular surface staining in dry eye syndrome
- Authors:
- Courrier, Emilie
Renault, Didier
Kaspi, Mathilde
Marcon, Agathe
Lambert, Victor
Garcin, Thibaud
Chiambaretta, Frederic
Garhofer, Gerhard
Thuret, Gilles
Gain, Philippe - Abstract:
- Abstract: Purpose: To describe and validate the micro‐instillation of fluorescein on the ocular surface by a disposable calibrated inoculation loop to improve corneal and conjunctival staining quality. Methods: Accuracy and precision of the volume of 0.5% sodium fluorescein collected by a single use 1 μ l‐calibrated inoculation loop were measured using a precision balance. Twenty patients (40 eyes) suffering from dry eye syndrome were enrolled in a prospective interventional nonrandomized study. Fluorescein was instilled with the loop, and slit‐lamp images were taken within 30 seconds using cobalt blue light with and without a yellow barrier filter. For comparison, after a washout period, the same images were retaken after instillation of one drop of fluorescein from a single‐dose unit. The main outcome measure was the staining quality assessed by three experts, blind to the instillation method. Patient discomfort (tolerance, by a questionnaire) was also compared. Results: The mean volume collected by the loop was 1.18 ± 0.12 μ l, compared with 33.70 ± 6.10 μ l using the single‐dose unit. The loop avoided excess dye responsible for unpleasant tearing, masking of lesions and rapid diffusion into the stroma. Micro‐instillation greatly improved image quality without losing information. The yellow filter further improved image contrast. Tolerance was excellent. Conclusion: The 1 μ l‐calibrated inoculation loop is a safe, convenient, inexpensive, disposable, sterile,Abstract: Purpose: To describe and validate the micro‐instillation of fluorescein on the ocular surface by a disposable calibrated inoculation loop to improve corneal and conjunctival staining quality. Methods: Accuracy and precision of the volume of 0.5% sodium fluorescein collected by a single use 1 μ l‐calibrated inoculation loop were measured using a precision balance. Twenty patients (40 eyes) suffering from dry eye syndrome were enrolled in a prospective interventional nonrandomized study. Fluorescein was instilled with the loop, and slit‐lamp images were taken within 30 seconds using cobalt blue light with and without a yellow barrier filter. For comparison, after a washout period, the same images were retaken after instillation of one drop of fluorescein from a single‐dose unit. The main outcome measure was the staining quality assessed by three experts, blind to the instillation method. Patient discomfort (tolerance, by a questionnaire) was also compared. Results: The mean volume collected by the loop was 1.18 ± 0.12 μ l, compared with 33.70 ± 6.10 μ l using the single‐dose unit. The loop avoided excess dye responsible for unpleasant tearing, masking of lesions and rapid diffusion into the stroma. Micro‐instillation greatly improved image quality without losing information. The yellow filter further improved image contrast. Tolerance was excellent. Conclusion: The 1 μ l‐calibrated inoculation loop is a safe, convenient, inexpensive, disposable, sterile, well‐tolerated tool for reproducible micro‐instillation of commercial fluorescein. By greatly improving staining quality, it will help standardize assessment of dry eye severity. … (more)
- Is Part Of:
- Acta ophthalmologica. Volume 96:Issue 2(2018)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 96:Issue 2(2018)
- Issue Display:
- Volume 96, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 96
- Issue:
- 2
- Issue Sort Value:
- 2018-0096-0002-0000
- Page Start:
- e140
- Page End:
- e146
- Publication Date:
- 2017-10-25
- Subjects:
- calibrated inoculation loop -- cornea -- dry eye -- fluorescein -- micro‐instillation
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.13559 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5904.xml