Steady‐state pattern electroretinogram and short‐duration transient visual evoked potentials in glaucomatous and healthy eyes. (20th July 2017)
- Record Type:
- Journal Article
- Title:
- Steady‐state pattern electroretinogram and short‐duration transient visual evoked potentials in glaucomatous and healthy eyes. (20th July 2017)
- Main Title:
- Steady‐state pattern electroretinogram and short‐duration transient visual evoked potentials in glaucomatous and healthy eyes
- Authors:
- Amarasekera, Dilru C
Resende, Arthur F
Waisbourd, Michael
Puri, Sanjeev
Moster, Marlene R
Hark, Lisa A
Katz, L Jay
Fudemberg, Scott J
Mantravadi, Anand V - Abstract:
- Abstract: Importance: This study evaluates two rapid electrophysiological glaucoma diagnostic tests that may add a functional perspective to glaucoma diagnosis. Background: This study aimed to determine the ability of two office‐based electrophysiological diagnostic tests, steady‐state pattern electroretinogram and short‐duration transient visual evoked potentials, to discern between glaucomatous and healthy eyes. Design: This is a cross‐sectional study in a hospital setting. Participants: Forty‐one patients with glaucoma and 41 healthy volunteers participated in the study. Methods: Steady‐state pattern electroretinogram and short‐duration transient visual evoked potential testing was conducted in glaucomatous and healthy eyes. A 64‐bar‐size stimulus with both a low‐contrast and high‐contrast setting was used to compare steady‐state pattern electroretinogram parameters in both groups. A low‐contrast and high‐contrast checkerboard stimulus was used to measure short‐duration transient visual evoked potential parameters in both groups. Main Outcome Measures: Steady‐state pattern electroretinogram parameters compared were MagnitudeD, MagnitudeD/Magnitude ratio, and the signal‐to‐noise ratio. Short‐duration transient visual evoked potential parameters compared were amplitude and latency. Results: MagnitudeD was significantly lower in glaucoma patients when using a low‐contrast ( P = 0.001) and high‐contrast ( P < 0.001) 64‐bar‐size steady‐state pattern electroretinogramAbstract: Importance: This study evaluates two rapid electrophysiological glaucoma diagnostic tests that may add a functional perspective to glaucoma diagnosis. Background: This study aimed to determine the ability of two office‐based electrophysiological diagnostic tests, steady‐state pattern electroretinogram and short‐duration transient visual evoked potentials, to discern between glaucomatous and healthy eyes. Design: This is a cross‐sectional study in a hospital setting. Participants: Forty‐one patients with glaucoma and 41 healthy volunteers participated in the study. Methods: Steady‐state pattern electroretinogram and short‐duration transient visual evoked potential testing was conducted in glaucomatous and healthy eyes. A 64‐bar‐size stimulus with both a low‐contrast and high‐contrast setting was used to compare steady‐state pattern electroretinogram parameters in both groups. A low‐contrast and high‐contrast checkerboard stimulus was used to measure short‐duration transient visual evoked potential parameters in both groups. Main Outcome Measures: Steady‐state pattern electroretinogram parameters compared were MagnitudeD, MagnitudeD/Magnitude ratio, and the signal‐to‐noise ratio. Short‐duration transient visual evoked potential parameters compared were amplitude and latency. Results: MagnitudeD was significantly lower in glaucoma patients when using a low‐contrast ( P = 0.001) and high‐contrast ( P < 0.001) 64‐bar‐size steady‐state pattern electroretinogram stimulus. MagnitudeD/Magnitude ratio and SNR were significantly lower in the glaucoma group when using a high‐contrast 64‐bar‐size stimulus ( P < 0.001 and P = 0.010, respectively). Short‐duration transient visual evoked potential amplitude and latency were not significantly different between the two groups. Conclusions and relevance: Steady‐state pattern electroretinogram was effectively able to discern between glaucomatous and healthy eyes. Steady‐state pattern electroretinogram may thus have a role as a clinically useful electrophysiological diagnostic tool. … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 46:Number 1(2018)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 46:Number 1(2018)
- Issue Display:
- Volume 46, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2018-0046-0001-0000
- Page Start:
- 54
- Page End:
- 61
- Publication Date:
- 2017-07-20
- Subjects:
- glaucoma -- short‐duration transient visual evoked potentials -- steady‐state pattern electroretinogram
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.13006 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5894.xml