The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators. (April 2018)
- Record Type:
- Journal Article
- Title:
- The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators. (April 2018)
- Main Title:
- The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators
- Authors:
- Arias Velásquez, Ricardo Manuel
Mejia Lara, Jennifer Vanessa - Abstract:
- Abstract: The flashovers on insulators, caused by severe pollution, has posed the biggest threat on the safe operation of power systems the insulators contamination, and it is an important problem, special in polluted. The aperiodic occurrence of widespread contamination related outages cause serious damages to the transmission lines, the worst behavior is up to 500 kV overhead lines. The exceptional level of pollution measured on those insulators, especially for the bottom surface for the non-soluble salt deposit density (NSDD) component, where the values are outside of the standard limit given in the currently IEC standard. The results provide important reference for the insulators design, maintenance of operational transmission line insulators and flashover warnings. It should be highlighted that results fall out of the limit of the IEC standard and that in order to plot those values in the graph the limits for the highest NSDD values have been increased from 4 to 20 g/cm 2 . This clearly shows the unusually high values of the NSDD components measured on those insulators. The case study has been realized on 837, 000 insulators for 9000 towers in 500 kV powers lines. This clearly shows the unusual characteristics of the coast and desert environment of the 500 kV overhead lines, and the needs of update in the IEC standards has been researched. Highlights: The flashovers on insulators, caused by severe pollution, has posed the biggest threat on the safe operation. UnusualAbstract: The flashovers on insulators, caused by severe pollution, has posed the biggest threat on the safe operation of power systems the insulators contamination, and it is an important problem, special in polluted. The aperiodic occurrence of widespread contamination related outages cause serious damages to the transmission lines, the worst behavior is up to 500 kV overhead lines. The exceptional level of pollution measured on those insulators, especially for the bottom surface for the non-soluble salt deposit density (NSDD) component, where the values are outside of the standard limit given in the currently IEC standard. The results provide important reference for the insulators design, maintenance of operational transmission line insulators and flashover warnings. It should be highlighted that results fall out of the limit of the IEC standard and that in order to plot those values in the graph the limits for the highest NSDD values have been increased from 4 to 20 g/cm 2 . This clearly shows the unusually high values of the NSDD components measured on those insulators. The case study has been realized on 837, 000 insulators for 9000 towers in 500 kV powers lines. This clearly shows the unusual characteristics of the coast and desert environment of the 500 kV overhead lines, and the needs of update in the IEC standards has been researched. Highlights: The flashovers on insulators, caused by severe pollution, has posed the biggest threat on the safe operation. Unusual contamination characteristics of the coast and desert environment of the overhead line. Needs of creation of a new minimum nominal creepage distance. … (more)
- Is Part Of:
- Engineering failure analysis. Volume 86(2018)
- Journal:
- Engineering failure analysis
- Issue:
- Volume 86(2018)
- Issue Display:
- Volume 86, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 86
- Issue:
- 2018
- Issue Sort Value:
- 2018-0086-2018-0000
- Page Start:
- 21
- Page End:
- 32
- Publication Date:
- 2018-04
- Subjects:
- Insulators -- Pollution -- Overhead lines
System failures (Engineering) -- Periodicals
Fracture mechanics -- Periodicals
Reliability (Engineering) -- Periodicals
Pannes -- Périodiques
Rupture, Mécanique de la -- Périodiques
Fiabilité -- Périodiques
Fracture mechanics
Reliability (Engineering)
System failures (Engineering)
Periodicals
Electronic journals
620.112 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13506307 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engfailanal.2017.12.018 ↗
- Languages:
- English
- ISSNs:
- 1350-6307
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3760.991000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5878.xml