Results of an international comparison of activity measurements of 68Ge. (April 2018)
- Record Type:
- Journal Article
- Title:
- Results of an international comparison of activity measurements of 68Ge. (April 2018)
- Main Title:
- Results of an international comparison of activity measurements of 68Ge
- Authors:
- Cessna, J.T.
Fitzgerald, R.
Zimmerman, B.E.
Laureano-Pérez, L.
Bergeron, D.E.
van Wyngaardt, F.
Smith, M.
Jackson, T.
Howe, B.
da Silva, C.J.
Iwahara, A.
da Cruz, P.A.L.
Zhang, M.
Liu, H.
Liang, J.
Fréchou, C.
Bobin, C.
Cassette, P.
Kossert, K.
Nähle, O.
Marganiec-Gałązka, J.
Joseph, L.
Ravindra, A.
Kulkarni, D.N.
Yunoki, A.
Sato, Y.
Lee, K.B.
Lee, J.M.
Agung,
Dziel, T.
Listkowska, A.
Tymiński, Z.
Sahagia, M.
Antohe, A.
Ioan, M.-R.
Luca, A.
Krivosek, M.
Ometakova, J.
Javornik, A.
Zalesakova, M.
García-Toraño Martinez, E.
Roteta, M.
Mejuto, M.
Nedjadi, Y.
Juget, F.
Yuan, M.-C.
Yeh, C.Y.
Yeltepe, E.
Dirican, A.
Keightley, J.
Pearce, A.
… (more) - Abstract:
- Abstract: An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68 Ge/ 68 Ga solution. Results for the activity concentration, C A, of 68 Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)β-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11) kBq g −1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6 mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence. Highlights: An international comparison of the activity of solution was carried out for 68 Ge/ 68 Ga. Results were submitted by 17 participants. Results were submitted for 8 primary methods and 3 secondary methods. The majority of results are in agreement, with two outliers. TheAbstract: An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68 Ge/ 68 Ga solution. Results for the activity concentration, C A, of 68 Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)β-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11) kBq g −1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6 mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence. Highlights: An international comparison of the activity of solution was carried out for 68 Ge/ 68 Ga. Results were submitted by 17 participants. Results were submitted for 8 primary methods and 3 secondary methods. The majority of results are in agreement, with two outliers. The ability to standardize 68 Ge/ 68 Ga has been demonstrated. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 134(2018:Apr.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 134(2018:Apr.)
- Issue Display:
- Volume 134 (2018)
- Year:
- 2018
- Volume:
- 134
- Issue Sort Value:
- 2018-0134-0000-0000
- Page Start:
- 385
- Page End:
- 390
- Publication Date:
- 2018-04
- Subjects:
- International comparison -- Equivalence -- Germanium-68 -- Gallium-68
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2017.10.052 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5878.xml