Evaluation and comparison of second-check monitor unit calculation software with Pinnacle3 treatment planning system. (January 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation and comparison of second-check monitor unit calculation software with Pinnacle3 treatment planning system. (January 2018)
- Main Title:
- Evaluation and comparison of second-check monitor unit calculation software with Pinnacle3 treatment planning system
- Authors:
- Tuazon, B.
Narayanasamy, G.
Papanikolaou, N.
Kirby, N.
Mavroidis, P.
Stathakis, S. - Abstract:
- Highlights: Redundant independent dose calculations is a necessary part of a radiotherapy treatment. Comparison of TPS dose calculations against a simpler and efficient algorithm is a vital part of QA. Multiple second check softwares are available for commercial use. Our study compares four second check softwares against the Pinnacle 3 dose computations. Abstract: The purpose of this study was to evaluate and compare the accuracy of dose calculations in second check softwares (Diamond, IMSure, MuCheck, and RadCalc) against the Phillips Pinnacle 3 treatment planning system. Eighteen previously treated patients' treatment planning files consisting of a total of 204 beams were exported from the Pinnacle 3 TPS to each of the four second check software. Of these beams, 145 of the beams used were IMRT plans while 59 were VMAT arcs. The values were represented as a percent difference between primary and secondary calculations and used for statistical analysis. Box plots, Pearson Correlation, and Bland-Altman analysis were performed in MedCalc. The mean percent difference in calculated dose for Diamond, IMSure, MuCheck, and RadCalc from Pinnacle 3 were −0.67%, 0.31%, 1.51% and −0.36%, respectively. The corresponding variances were calculated to be 0.07%, 0.13%, 0.08%, and 0.03%; and the largest percent differences were −7.9%, 9.70%, 9.39%, and 5.45%. The dose differences of each of the second check software in this study can vary considerably and VMAT plans have larger differencesHighlights: Redundant independent dose calculations is a necessary part of a radiotherapy treatment. Comparison of TPS dose calculations against a simpler and efficient algorithm is a vital part of QA. Multiple second check softwares are available for commercial use. Our study compares four second check softwares against the Pinnacle 3 dose computations. Abstract: The purpose of this study was to evaluate and compare the accuracy of dose calculations in second check softwares (Diamond, IMSure, MuCheck, and RadCalc) against the Phillips Pinnacle 3 treatment planning system. Eighteen previously treated patients' treatment planning files consisting of a total of 204 beams were exported from the Pinnacle 3 TPS to each of the four second check software. Of these beams, 145 of the beams used were IMRT plans while 59 were VMAT arcs. The values were represented as a percent difference between primary and secondary calculations and used for statistical analysis. Box plots, Pearson Correlation, and Bland-Altman analysis were performed in MedCalc. The mean percent difference in calculated dose for Diamond, IMSure, MuCheck, and RadCalc from Pinnacle 3 were −0.67%, 0.31%, 1.51% and −0.36%, respectively. The corresponding variances were calculated to be 0.07%, 0.13%, 0.08%, and 0.03%; and the largest percent differences were −7.9%, 9.70%, 9.39%, and 5.45%. The dose differences of each of the second check software in this study can vary considerably and VMAT plans have larger differences than IMRT. Among the four second check softwares, RadCalc values has shown a high agreement on average with low variation, and had the smallest percent range from Pinnacle 3 values. The closest in average percent difference from the Pinnacle 3 data was the IMSure software, but suffered from significantly larger variance and percent range. The values reported by Diamond and MuCheck had significantly high percent differences with TPS values. … (more)
- Is Part Of:
- Physica medica. Volume 45(2018)
- Journal:
- Physica medica
- Issue:
- Volume 45(2018)
- Issue Display:
- Volume 45, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 2018
- Issue Sort Value:
- 2018-0045-2018-0000
- Page Start:
- 186
- Page End:
- 191
- Publication Date:
- 2018-01
- Subjects:
- 2nd Check -- Monitor unit check -- MU validation -- Independent MU verification -- TPS QA
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.12.004 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5857.xml