A Graphene Oxide‐DNA Electrochemical Sensor Based on Glassy Carbon Electrode for Sensitive Determination of Methotrexate. Issue 2 (13th December 2017)
- Record Type:
- Journal Article
- Title:
- A Graphene Oxide‐DNA Electrochemical Sensor Based on Glassy Carbon Electrode for Sensitive Determination of Methotrexate. Issue 2 (13th December 2017)
- Main Title:
- A Graphene Oxide‐DNA Electrochemical Sensor Based on Glassy Carbon Electrode for Sensitive Determination of Methotrexate
- Authors:
- Chen, Jincheng
Fu, Bo
Liu, Tailin
Yan, Zhihong
Li, Kang - Abstract:
- Abstract: Methotrexate (MTX) was used as an anti‐cancer drug, but its excessive use can cause serious side effects, it was necessary to monitor MTX in vivo . In this report, DNA was immobilized on a glassy carbon electrode (GCE) modified with graphene oxide (GO) to develop an electrochemical sensor for sensitive determination of MTX for the first time. The adsorptive voltammetric behaviors of MTX on DNA sensor were investigated using differential pulse voltammetry (DPV). The peak current response of guanine in DNA was used as a determination signal of MTX in acetate buffer solution pH 4.6. Voltammetric investigations revealed that the proposed method could determine MTX in the concentration range from 5.5×10 −8 to 2.2×10 −6 mol L −1 with a lower detection limit of 7.6×10 − 9 mol L −1 (S/N=3). The method was applied to detect MTX in human blood serum and diluted urine samples with excellent recoveries of 97.4–102.5 %. Compared with the previous studies, the DNA/GO/GCE electrode constructed by us based on the change rate of guanine current (R%) in DNA, proportionally reflecting the MTX concentration, is simple andsensitive . Abstract :
- Is Part Of:
- Electroanalysis. Volume 30:Issue 2(2018)
- Journal:
- Electroanalysis
- Issue:
- Volume 30:Issue 2(2018)
- Issue Display:
- Volume 30, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 30
- Issue:
- 2
- Issue Sort Value:
- 2018-0030-0002-0000
- Page Start:
- 288
- Page End:
- 295
- Publication Date:
- 2017-12-13
- Subjects:
- Methotrexate -- DNA -- Graphene oxide -- Biological samples
Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201700615 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5845.xml