Biological quality control for extracorporeal photochemotherapy: Assessing mononuclear cell apoptosis levels in ECP bags of chronic GvHD patients. Issue 3 (15th September 2014)
- Record Type:
- Journal Article
- Title:
- Biological quality control for extracorporeal photochemotherapy: Assessing mononuclear cell apoptosis levels in ECP bags of chronic GvHD patients. Issue 3 (15th September 2014)
- Main Title:
- Biological quality control for extracorporeal photochemotherapy: Assessing mononuclear cell apoptosis levels in ECP bags of chronic GvHD patients
- Authors:
- Taverna, Francesca
Coluccia, Paola
Arienti, Flavio
Birolini, Annalisa
Terranova, Laura
Mazzocchi, Arabella
Rini, Francesca
Mariani, Luigi
Melani, Cecilia
Ravagnani, Fernando - Abstract:
- Abstract : Extracorporeal photochemotherapy (ECP) is a treatment approved by the FDA for cutaneous T‐cell lymphoma, and it is currently used off‐label for graft‐versus‐host disease (GvHD) and other conditions. In agreement with good practices for the therapeutic use of human cells, quality control has to be performed to validate the ECP procedure with the off‐line technique. Since no gold‐standard biological test is available, we assessed the apoptosis generated in the ECP bag using a flow cytometric analysis. Thirty‐one ECP procedures performed on 13 patients with chronic GvHD were studied by monitoring the induction of mononuclear cell (MNC) apoptosis using annexin V/propidium iodide double staining; residual lymphocyte proliferation to standard mitogens was also measured in 17 of the procedures. The kinetics of apoptosis was analyzed at different times in MNCs untreated or treated with 8‐methoxy‐psoralen plus ultraviolet A; the variation (ΔAPOPTOSIS ) after 24 h revealed the efficacy of the treatment. In 88.6% of the 31 ECP procedures, ΔAPOPTOSIS was >15% (the "alerting" threshold for ΔAPOPTOSIS was set at 15% on the basis of our data); in the remainder (19.4%), the increment in apoptosis was lower. In four procedures, the proliferation assay was useful for assessing the effect of ECP on the apheretic bag. In conclusion, both flow cytometric assays enabled a biologically significant result to be obtained. In our opinion, the apoptosis test—being faster and easier than theAbstract : Extracorporeal photochemotherapy (ECP) is a treatment approved by the FDA for cutaneous T‐cell lymphoma, and it is currently used off‐label for graft‐versus‐host disease (GvHD) and other conditions. In agreement with good practices for the therapeutic use of human cells, quality control has to be performed to validate the ECP procedure with the off‐line technique. Since no gold‐standard biological test is available, we assessed the apoptosis generated in the ECP bag using a flow cytometric analysis. Thirty‐one ECP procedures performed on 13 patients with chronic GvHD were studied by monitoring the induction of mononuclear cell (MNC) apoptosis using annexin V/propidium iodide double staining; residual lymphocyte proliferation to standard mitogens was also measured in 17 of the procedures. The kinetics of apoptosis was analyzed at different times in MNCs untreated or treated with 8‐methoxy‐psoralen plus ultraviolet A; the variation (ΔAPOPTOSIS ) after 24 h revealed the efficacy of the treatment. In 88.6% of the 31 ECP procedures, ΔAPOPTOSIS was >15% (the "alerting" threshold for ΔAPOPTOSIS was set at 15% on the basis of our data); in the remainder (19.4%), the increment in apoptosis was lower. In four procedures, the proliferation assay was useful for assessing the effect of ECP on the apheretic bag. In conclusion, both flow cytometric assays enabled a biologically significant result to be obtained. In our opinion, the apoptosis test—being faster and easier than the proliferation test—could be a reliable way to validate ECP procedures. J. Clin. Apheresis 30:162–170, 2015. © 2014 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Journal of clinical apheresis. Volume 30:Issue 3(2015)
- Journal:
- Journal of clinical apheresis
- Issue:
- Volume 30:Issue 3(2015)
- Issue Display:
- Volume 30, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2015-0030-0003-0000
- Page Start:
- 162
- Page End:
- 170
- Publication Date:
- 2014-09-15
- Subjects:
- ECP -- flow cytometry -- annexin V/PI -- CFSE
Hemapheresis -- Periodicals
Blood -- Transfusion -- Periodicals
Blood -- Transfusion, Autologous -- Periodicals
Cell separation -- Periodicals
Leukapheresis -- Periodicals
Plasmapheresis -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-1101 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jca.21357 ↗
- Languages:
- English
- ISSNs:
- 0733-2459
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.381500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5846.xml