Absorbed dose kernel and self‐shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization. Issue 2 (25th December 2017)
- Record Type:
- Journal Article
- Title:
- Absorbed dose kernel and self‐shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization. Issue 2 (25th December 2017)
- Main Title:
- Absorbed dose kernel and self‐shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization
- Authors:
- Church, Cody
Mawko, George
Archambault, John Paul
Lewandowski, Robert
Liu, David
Kehoe, Sharon
Boyd, Daniel
Abraham, Robert
Syme, Alasdair - Abstract:
- Abstract : Purpose: Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x‐ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long‐lived contaminant radionuclides while concurrently quantifying the self‐shielding of the glass network. Methods: Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self‐shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Results: Self‐shielding varies with time postremoval from the reactor. At early time points, it is less pronouncedAbstract : Purpose: Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x‐ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long‐lived contaminant radionuclides while concurrently quantifying the self‐shielding of the glass network. Methods: Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self‐shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Results: Self‐shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4–2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self‐shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the microspheres based on weighted activities. The shapes of the absorbed dose kernels are dominated at short times postactivation by the contributions of 70 Ga and 72 Ga. Following decay of the short‐lived contaminants, the absorbed dose kernel is effectively that of 90 Y. After approximately 1000 h postactivation, the contributions of 85 Sr and 89 Sr become increasingly dominant, though the absorbed dose‐rate around the beads drops by roughly four orders of magnitude. Conclusions: The introduction of high atomic number elements for the purpose of increasing radiopacity necessarily leads to the production of radionuclides other than 90 Y in the microspheres. Most of the radionuclides in this study are short‐lived and are likely not of any significant concern for this therapeutic agent. The presence of small quantities of longer lived radionuclides will change the shape of the absorbed dose kernel around a microsphere at long time points postadministration when activity levels are significantly reduced. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 2(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 2(2018)
- Issue Display:
- Volume 45, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 2
- Issue Sort Value:
- 2018-0045-0002-0000
- Page Start:
- 934
- Page End:
- 942
- Publication Date:
- 2017-12-25
- Subjects:
- absorbed dose kernel -- glass microsphere -- self‐shielding -- transarterial radioembolization -- yttrium‐90
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12717 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5831.xml