Ambulatory diagnostic ECG monitoring for syncope and collapse: An assessment of clinical practice in the United States. Issue 2 (24th January 2018)
- Record Type:
- Journal Article
- Title:
- Ambulatory diagnostic ECG monitoring for syncope and collapse: An assessment of clinical practice in the United States. Issue 2 (24th January 2018)
- Main Title:
- Ambulatory diagnostic ECG monitoring for syncope and collapse: An assessment of clinical practice in the United States
- Authors:
- Benditt, David G.
Adkisson, Wayne O.
Sutton, Richard
Mears, Robin K.
Sakaguchi, Scott - Abstract:
- Abstract: Introduction: Diagnostic ambulatory electrocardiogram (AECG) monitoring is widely used for evaluating syncope and collapse, and practice guidelines provide recommendations regarding optimal AECG device selection. However, whether physicians utilize AECGs in accordance with the pertinent guidelines is unclear. This study assessed utilization of AECG monitoring systems for syncope and collapse diagnosis by physicians in the United States. Methods and results: A quantitative survey was undertaken of physicians comprising multiple specialties (emergency department, n = 35; primary care, n = 35; hospitalists, n = 30; neurologists, n = 30; nonimplanting, n = 34, and implanting‐cardiologists, n = 35). Depending on specialty, respondents reported that neural‐reflex and orthostatic causes accounted for 17–23%, cardiac causes for 12–20%, and "neurological causes" (specifically psychogenic pseudo‐syncope/pseudo‐seizures and acute cerebrovascular conditions) for 7–12% of their syncope/collapse cases. The choice of AECG technology varied by specialty. Thus, despite patients having daily symptoms, 25% of respondents chose an AECG technology other than a Holter‐type monitor. Conversely, when monitoring for infrequent events (e.g., less than monthly), 12–18% indicated that they would choose a 24‐ to 48‐hour Holter, 20–34% would choose either a conventional event recorder or a mobile cardiac telemetry system, and only 53–65% would select an insertable cardiac monitor. Conclusions:Abstract: Introduction: Diagnostic ambulatory electrocardiogram (AECG) monitoring is widely used for evaluating syncope and collapse, and practice guidelines provide recommendations regarding optimal AECG device selection. However, whether physicians utilize AECGs in accordance with the pertinent guidelines is unclear. This study assessed utilization of AECG monitoring systems for syncope and collapse diagnosis by physicians in the United States. Methods and results: A quantitative survey was undertaken of physicians comprising multiple specialties (emergency department, n = 35; primary care, n = 35; hospitalists, n = 30; neurologists, n = 30; nonimplanting, n = 34, and implanting‐cardiologists, n = 35). Depending on specialty, respondents reported that neural‐reflex and orthostatic causes accounted for 17–23%, cardiac causes for 12–20%, and "neurological causes" (specifically psychogenic pseudo‐syncope/pseudo‐seizures and acute cerebrovascular conditions) for 7–12% of their syncope/collapse cases. The choice of AECG technology varied by specialty. Thus, despite patients having daily symptoms, 25% of respondents chose an AECG technology other than a Holter‐type monitor. Conversely, when monitoring for infrequent events (e.g., less than monthly), 12–18% indicated that they would choose a 24‐ to 48‐hour Holter, 20–34% would choose either a conventional event recorder or a mobile cardiac telemetry system, and only 53–65% would select an insertable cardiac monitor. Conclusions: In evaluation of syncope/collapse, most U.S. clinicians across specialties use AECGs appropriately, but in a substantial minority there remains discordance between choice of AECG technology and guideline‐based recommendations. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 41:Issue 2(2018)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 41:Issue 2(2018)
- Issue Display:
- Volume 41, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2018-0041-0002-0000
- Page Start:
- 203
- Page End:
- 209
- Publication Date:
- 2018-01-24
- Subjects:
- ambulatory ECG monitoring -- collapse -- syncope
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13265 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5831.xml