Accuracy improvement of boron by molecular emission with a genetic algorithm and partial least squares regression model in laser-induced breakdown spectroscopy. Issue 2 (4th January 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy improvement of boron by molecular emission with a genetic algorithm and partial least squares regression model in laser-induced breakdown spectroscopy. Issue 2 (4th January 2018)
- Main Title:
- Accuracy improvement of boron by molecular emission with a genetic algorithm and partial least squares regression model in laser-induced breakdown spectroscopy
- Authors:
- Zhu, Zhihao
Li, Jiaming
Guo, Yangmin
Cheng, Xiao
Tang, Yun
Guo, Lianbo
Li, Xiangyou
Lu, Yongfeng
Zeng, Xiaoyan - Abstract:
- Abstract : We chose BO molecular emission to reduce the self-absorption effect in atomic LIBS and applied GA-PLSR to improve the molecular calibration. Abstract : Laser-induced breakdown spectroscopy (LIBS) is an atomic emission spectrometry technique for material component analysis. However, the spectral signal distortion and the low analytical accuracy remain as challenges due to the self-absorption effect of atomic lines in LIBS. Here, to overcome this flaw, we demonstrated a method to build calibration with molecular emission, which was measured from a mixture of H3 BO3 and C6 H12 O6 ·H2 O in powder form. We compared the calibration established by typical atomic emission and molecular emission of boron monoxide. The results showed that the self-absorption effect and R 2 values were improved by using molecular spectra. Furthermore, to improve the accuracy of molecular emission content determination, a genetic algorithm and partial least squares regression (GA-PLSR) combination model was adopted. The achieved root mean square error of prediction (RMSEP) and the mean prediction error (MPE) for the GA-PLSR model were 0.8667 wt% and 10.9685%, respectively. The results demonstrated that it is a potential method to overcome the self-absorption effect with molecular emission and the accuracy of boron content determination of molecular emission can be improved with the GA-PLSR model.
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 33:Issue 2(2018)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 33:Issue 2(2018)
- Issue Display:
- Volume 33, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2018-0033-0002-0000
- Page Start:
- 205
- Page End:
- 209
- Publication Date:
- 2018-01-04
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ja00356k ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5822.xml