Estimating the density of femoral head trabecular bone from hip fracture patients using computed tomography scan data. (June 2014)
- Record Type:
- Journal Article
- Title:
- Estimating the density of femoral head trabecular bone from hip fracture patients using computed tomography scan data. (June 2014)
- Main Title:
- Estimating the density of femoral head trabecular bone from hip fracture patients using computed tomography scan data
- Authors:
- Vivanco, Juan F
Burgers, Travis A
García-Rodríguez, Sylvana
Crookshank, Meghan
Kunz, Manuela
MacIntyre, Norma J
Harrison, Mark M
Bryant, J Tim
Sellens, Rick W
Ploeg, Heidi-Lynn - Abstract:
- The purpose of this study was to compare computed tomography density ( ρCT ) obtained using typical clinical computed tomography scan parameters to ash density ( ρash ), for the prediction of densities of femoral head trabecular bone from hip fracture patients. An experimental study was conducted to investigate the relationships between ρash and ρCT and between each of these densities and ρbulk and ρdry . Seven human femoral heads from hip fracture patients were computed tomography–scanned ex vivo, and 76 cylindrical trabecular bone specimens were collected. Computed tomography density was computed from computed tomography images by using a calibration Hounsfield units–based equation, whereas ρbulk, ρdry and ρash were determined experimentally. A large variation was found in the mean Hounsfield units of the bone cores (HUcore ) with a constant bias from ρCT to ρash of 42.5 mg/cm 3 . Computed tomography and ash densities were linearly correlated ( R 2 = 0.55, p < 0.001). It was demonstrated that ρash provided a good estimate of ρbulk ( R 2 = 0.78, p < 0.001) and is a strong predictor of ρdry ( R 2 = 0.99, p < 0.001). In addition, the ρCT was linearly related to ρbulk ( R 2 = 0.43, p < 0.001) and ρdry ( R 2 = 0.56, p < 0.001). In conclusion, mineral density was an appropriate predictor of ρbulk and ρdry, and ρCT was not a surrogate for ρash . There were linear relationships between ρCT and physical densities; however, following the experimental protocols of this study toThe purpose of this study was to compare computed tomography density ( ρCT ) obtained using typical clinical computed tomography scan parameters to ash density ( ρash ), for the prediction of densities of femoral head trabecular bone from hip fracture patients. An experimental study was conducted to investigate the relationships between ρash and ρCT and between each of these densities and ρbulk and ρdry . Seven human femoral heads from hip fracture patients were computed tomography–scanned ex vivo, and 76 cylindrical trabecular bone specimens were collected. Computed tomography density was computed from computed tomography images by using a calibration Hounsfield units–based equation, whereas ρbulk, ρdry and ρash were determined experimentally. A large variation was found in the mean Hounsfield units of the bone cores (HUcore ) with a constant bias from ρCT to ρash of 42.5 mg/cm 3 . Computed tomography and ash densities were linearly correlated ( R 2 = 0.55, p < 0.001). It was demonstrated that ρash provided a good estimate of ρbulk ( R 2 = 0.78, p < 0.001) and is a strong predictor of ρdry ( R 2 = 0.99, p < 0.001). In addition, the ρCT was linearly related to ρbulk ( R 2 = 0.43, p < 0.001) and ρdry ( R 2 = 0.56, p < 0.001). In conclusion, mineral density was an appropriate predictor of ρbulk and ρdry, and ρCT was not a surrogate for ρash . There were linear relationships between ρCT and physical densities; however, following the experimental protocols of this study to determine ρCT, considerable scatter was present in the ρCT relationships. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 228:Number 6(2014:Jun.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 228:Number 6(2014:Jun.)
- Issue Display:
- Volume 228, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 228
- Issue:
- 6
- Issue Sort Value:
- 2014-0228-0006-0000
- Page Start:
- 616
- Page End:
- 626
- Publication Date:
- 2014-06
- Subjects:
- Computed tomography -- femoral head -- trabecular bone -- bone density -- X-ray attenuation
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411914540285 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5809.xml