Mechanical and structural characterization of tibial prosthetic interfaces before and after aging under simulated service conditions. (March 2015)
- Record Type:
- Journal Article
- Title:
- Mechanical and structural characterization of tibial prosthetic interfaces before and after aging under simulated service conditions. (March 2015)
- Main Title:
- Mechanical and structural characterization of tibial prosthetic interfaces before and after aging under simulated service conditions
- Authors:
- Cavaco, A.
Ramalho, A.
Pais, S.
Durães, L. - Abstract:
- Abstract: Prosthesis interface is one of the most important components to promote individual׳s health and comfort, as it establishes direct contact with the skin and transfers loads generated during gait. The aim of this study was to mechanically characterize, three commercial interfaces (block copolymer, silicone gel and silicone elestomer), under static and dynamic conditions, before and after undergoing a process of chemical aging in synthetic sweat for periods up to 90 days. Static mechanical compression tests were performed on the materials, as well as fatigue tests to assess their static and dynamic mechanical behaviors, respectively. For the second, a sinusoidal load was applied with an appropriate range of deformation for each material. Several analytical techniques were also used to characterize the materials, namely Fourier Transform Infrared Spectroscopy (FTIR), X-ray diffraction (XRD), and morphology characterization by Scanning Electron Microscopy (SEM). All the tested materials have strong viscoelastic behavior, showing a linear response for small deformations, followed by a nonlinear behavior for higher deformation. The block copolymer and the silicone gel are affected by aging in synthetic sweat in a similar way, with a significant increase of their rigidity after 30 days, followed by a progressive reduction. The silicone elastomer displays a continuous increase of rigidity along the 90 days of storage, being the most sensitive to aging affects. It alsoAbstract: Prosthesis interface is one of the most important components to promote individual׳s health and comfort, as it establishes direct contact with the skin and transfers loads generated during gait. The aim of this study was to mechanically characterize, three commercial interfaces (block copolymer, silicone gel and silicone elestomer), under static and dynamic conditions, before and after undergoing a process of chemical aging in synthetic sweat for periods up to 90 days. Static mechanical compression tests were performed on the materials, as well as fatigue tests to assess their static and dynamic mechanical behaviors, respectively. For the second, a sinusoidal load was applied with an appropriate range of deformation for each material. Several analytical techniques were also used to characterize the materials, namely Fourier Transform Infrared Spectroscopy (FTIR), X-ray diffraction (XRD), and morphology characterization by Scanning Electron Microscopy (SEM). All the tested materials have strong viscoelastic behavior, showing a linear response for small deformations, followed by a nonlinear behavior for higher deformation. The block copolymer and the silicone gel are affected by aging in synthetic sweat in a similar way, with a significant increase of their rigidity after 30 days, followed by a progressive reduction. The silicone elastomer displays a continuous increase of rigidity along the 90 days of storage, being the most sensitive to aging affects. It also exhibits the lowest stiffness value, being suitable for uses that require maximum comfort. All materials demonstrate chemical and structural stability under service simulated conditions. Graphical abstract: Highlights: Silicone-based and copolymer interfaces for prosthesis were mechanically tested. Interfaces show chemical stability under service conditions – load, aging in sweat. Changes in the structural organization of the material occur with aging. Interface with lower stiffness (silicone elastomer) is more sensitive to aging. Interfaces with lowest stiffness are suitable for uses requiring maximum comfort. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 43(2015)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 43(2015)
- Issue Display:
- Volume 43, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 2015
- Issue Sort Value:
- 2015-0043-2015-0000
- Page Start:
- 78
- Page End:
- 90
- Publication Date:
- 2015-03
- Subjects:
- Tibial prosthesis -- Elastomeric interface materials -- Aging in sweat -- Dynamic-mechanical characterization
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2014.12.005 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5779.xml