Stress-relaxation and fatigue behaviour of synthetic brow-suspension materials. (February 2015)
- Record Type:
- Journal Article
- Title:
- Stress-relaxation and fatigue behaviour of synthetic brow-suspension materials. (February 2015)
- Main Title:
- Stress-relaxation and fatigue behaviour of synthetic brow-suspension materials
- Authors:
- Kwon, Kyung-Ah
Shipley, Rebecca J.
Edirisinghe, Mohan
Rayment, Andrew W.
Best, Serena M.
Cameron, Ruth E.
Salam, Tahrina
Rose, Geoffrey E.
Ezra, Daniel G. - Abstract:
- Abstract: Ptosis describes a low position of the upper eyelid. When this condition is due to poor function of the levator palpebrae superioris muscle, responsible for raising the lid, "brow-suspension" ptosis correction is usually performed, which involves internally attaching the malpositioned eyelid to the forehead musculature using brow-suspension materials. In service, such materials are exposed to both rapid tensile loading and unloading sequences during blinking, and a more sustained tensile strain during extended periods of closure. In this study, various mechanical tests were conducted to characterise and compare some of commonly-used synthetic brow-suspension materials (Prolene ®, Supramid Extra ® II, Silicone rods (Visitec ® Seiff frontalis suspension set) and Mersilene ® mesh) for their time-dependent response. At a given constant tensile strain or load, all of the brow-suspension materials exhibited stress-relaxation or creep, with Prolene ® having a statistically different relaxation or creep ratio as compared with those of others. Uniaxial tensile cyclic tests through preconditioning and fatigue tests demonstrated drastically different time-dependent response amongst the various materials. Although the tests generated hysteresis force–strain loops for all materials, the mechanical properties such as the number of cycles required to reach the steady-state, the reduction in the peak force, and the cyclic energy dissipation varied considerably. To reach theAbstract: Ptosis describes a low position of the upper eyelid. When this condition is due to poor function of the levator palpebrae superioris muscle, responsible for raising the lid, "brow-suspension" ptosis correction is usually performed, which involves internally attaching the malpositioned eyelid to the forehead musculature using brow-suspension materials. In service, such materials are exposed to both rapid tensile loading and unloading sequences during blinking, and a more sustained tensile strain during extended periods of closure. In this study, various mechanical tests were conducted to characterise and compare some of commonly-used synthetic brow-suspension materials (Prolene ®, Supramid Extra ® II, Silicone rods (Visitec ® Seiff frontalis suspension set) and Mersilene ® mesh) for their time-dependent response. At a given constant tensile strain or load, all of the brow-suspension materials exhibited stress-relaxation or creep, with Prolene ® having a statistically different relaxation or creep ratio as compared with those of others. Uniaxial tensile cyclic tests through preconditioning and fatigue tests demonstrated drastically different time-dependent response amongst the various materials. Although the tests generated hysteresis force–strain loops for all materials, the mechanical properties such as the number of cycles required to reach the steady-state, the reduction in the peak force, and the cyclic energy dissipation varied considerably. To reach the steady-state, Prolene ® and the silicone rod required the greatest and the least number of cycles, respectively. Furthermore, the fatigue tests at physiologically relevant conditions (15% strain controlled at 6.5 Hz) demonstrated that the reduction in the peak force during 100, 000 cycles ranged from 15% to 58%, with Prolene ® and the silicone rod exhibiting the greatest and the least value, respectively. Many factors need to be considered to select the most suitable brow-suspension material for ptosis correction. These novel data on the mechanical time-dependent performance could therefore help to guide clinicians in their decision-making process for optimal surgical outcome. Graphical abstract: Highlights: Mechanical behaviour of synthetic brow-suspension materials was investigated. Stress-relaxation properties of the materials have been compared. Fatigue of the materials was studied in physiologically relevant conditions. The findings have direct clinical implications in ptosis surgical outcome. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 42(2015)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 42(2015)
- Issue Display:
- Volume 42, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 2015
- Issue Sort Value:
- 2015-0042-2015-0000
- Page Start:
- 116
- Page End:
- 128
- Publication Date:
- 2015-02
- Subjects:
- Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2014.11.004 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5785.xml