Reliability and validity of a dual-probe personal computer-based muscle viewer for measuring the pennation angle of the medial gastrocnemius muscle in patients who have had a stroke. Issue 1 (2nd January 2018)
- Record Type:
- Journal Article
- Title:
- Reliability and validity of a dual-probe personal computer-based muscle viewer for measuring the pennation angle of the medial gastrocnemius muscle in patients who have had a stroke. Issue 1 (2nd January 2018)
- Main Title:
- Reliability and validity of a dual-probe personal computer-based muscle viewer for measuring the pennation angle of the medial gastrocnemius muscle in patients who have had a stroke
- Authors:
- Cho, Ji-Eun
Cho, Ki Hun
Yoo, Jun sang
Lee, Su Jin
Lee, Wan-Hee - Abstract:
- Abstract: Background: A dual-probe personal computer-based muscle viewer (DPC-BMW) is advantageous in that it is relatively lightweight and easy to apply. Objective: To investigate the reliability and validity of the DPC-BMW in comparison with those of a portable ultrasonography (P-US) device for measuring the pennation angle of the medial gastrocnemius (MG) muscle at rest and during contraction. Methods: Twenty-four patients who had a stroke (18 men and 6 women) participated in this study. Using the DPC-BMW and P-US device, the pennation angle of the MG muscle on the affected side was randomly measured. Two examiners randomly obtained the images of all the participants in two separate test sessions, 7 days apart. Intraclass correlation coefficient (ICC), confidence interval, standard error of measurement, Bland-Altman plot, and Pearson correlation coefficient were used to estimate their reliability and validity. Results: The ICC for the intrarater reliability of the MG muscle pennation angle measured using the DPC-BMW was > 0.916, indicating excellent reliability, and that for the interrater reliability ranged from 0.964 to 0.994. The P-US device also exhibited good reliability. A high correlation was found between the measurements of MG muscle pennation angle obtained using the DPC-BMW and that obtained using the P-US device ( p < 0.01). Conclusion: The DPC-BMW can provide clear images for accurate measurements, including measurements using dual probes. It has theAbstract: Background: A dual-probe personal computer-based muscle viewer (DPC-BMW) is advantageous in that it is relatively lightweight and easy to apply. Objective: To investigate the reliability and validity of the DPC-BMW in comparison with those of a portable ultrasonography (P-US) device for measuring the pennation angle of the medial gastrocnemius (MG) muscle at rest and during contraction. Methods: Twenty-four patients who had a stroke (18 men and 6 women) participated in this study. Using the DPC-BMW and P-US device, the pennation angle of the MG muscle on the affected side was randomly measured. Two examiners randomly obtained the images of all the participants in two separate test sessions, 7 days apart. Intraclass correlation coefficient (ICC), confidence interval, standard error of measurement, Bland-Altman plot, and Pearson correlation coefficient were used to estimate their reliability and validity. Results: The ICC for the intrarater reliability of the MG muscle pennation angle measured using the DPC-BMW was > 0.916, indicating excellent reliability, and that for the interrater reliability ranged from 0.964 to 0.994. The P-US device also exhibited good reliability. A high correlation was found between the measurements of MG muscle pennation angle obtained using the DPC-BMW and that obtained using the P-US device ( p < 0.01). Conclusion: The DPC-BMW can provide clear images for accurate measurements, including measurements using dual probes. It has the advantage of rehabilitative US imaging for individuals who have had a stroke. More research studies are needed to evaluate the usefulness of the DPC-BMW in rehabilitation. … (more)
- Is Part Of:
- Topics in stroke rehabilitation. Volume 25:Issue 1(2018)
- Journal:
- Topics in stroke rehabilitation
- Issue:
- Volume 25:Issue 1(2018)
- Issue Display:
- Volume 25, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2018-0025-0001-0000
- Page Start:
- 6
- Page End:
- 12
- Publication Date:
- 2018-01-02
- Subjects:
- Ultrasonography -- muscle architecture -- reliability -- gastrocnemius -- stroke
Cerebrovascular disease -- Patients -- Rehabilitation -- Periodicals
Cerebrovascular disease -- Periodicals
616.810305 - Journal URLs:
- http://thomasland.metapress.com/openurl.asp?genre=journal&issn=1074-9357 ↗
http://www.maneyonline.com/loi/tsr ↗
http://www.tandfonline.com/loi/ytsr20#.V6niC1JTF-V ↗
http://www.maneyonline.com ↗ - DOI:
- 10.1080/10749357.2017.1383723 ↗
- Languages:
- English
- ISSNs:
- 1074-9357
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8867.490300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5789.xml