Measurement of Orbital Biomechanical Properties in Patients with Thyroid Orbitopathy Using the Dynamic Scheimpflug Analyzer (Corvis ST). (4th March 2018)
- Record Type:
- Journal Article
- Title:
- Measurement of Orbital Biomechanical Properties in Patients with Thyroid Orbitopathy Using the Dynamic Scheimpflug Analyzer (Corvis ST). (4th March 2018)
- Main Title:
- Measurement of Orbital Biomechanical Properties in Patients with Thyroid Orbitopathy Using the Dynamic Scheimpflug Analyzer (Corvis ST)
- Authors:
- Leszczynska, Anna
Moehler, Karolin
Spoerl, Eberhard
Ramm, Lisa
Herber, Robert
Pillunat, Lutz E.
Terai, Naim - Abstract:
- ABSTRACT: Purpose : To investigate orbital biomechanical properties in patients with thyroid orbitopathy and in age- and gender-matched healthy subjects using the Corvis-ST (CST, Oculus Wetzlar, Germany). Methods : The CST allows a non-contact tonometry with an ultra-high-speed Scheimpflug device to record the deformation of the cornea during an air pulse. Biomechanical response parameters (intraocular pressure (IOP), whole eye movement length (WEMl) and time (WEMt), deflection amplitude 2 mm ratio max, deflection amplitude max, stiffness parameter, and biomechanically corrected IOP were measured in 39 patients with thyroid orbitopathy (= group I) and in 33 age- and gender-matched healthy subjects (= group II) using the CST. Results : Mean age in group I was 54.3 ± 11.6 years and in group II 54.2 ± 12.3 years with no statistical significant difference between the groups ( P = 0.98). The gender distribution between the groups was not statistically significantly different ( P = 0.51). Mean central corneal thickness was 571 ± 30 µm in group I and 563 ± 36 µm in group II ( P = 0.306). There were statistically significant differences ( P < 0.001) between groups I and II in mean IOP (19.3 ± 4.5 vs. 14.8 ± 2.3 mmHg, mean biomechanically corrected IOP (17.1 ± 3.4 vs. 13.4 ± 2.1 mmHg), mean WEMl (207 ± 57 vs. 322 ± 50 µm), mean WEMt (20.5 ± 1.0 vs. 21.9 ± 0.7 ms), mean IOP-adjusted WEMl (213 ± 56 vs. 314 ± 62 µm), and in mean stiffness parameter (132.5 ± 29.6 vs.ABSTRACT: Purpose : To investigate orbital biomechanical properties in patients with thyroid orbitopathy and in age- and gender-matched healthy subjects using the Corvis-ST (CST, Oculus Wetzlar, Germany). Methods : The CST allows a non-contact tonometry with an ultra-high-speed Scheimpflug device to record the deformation of the cornea during an air pulse. Biomechanical response parameters (intraocular pressure (IOP), whole eye movement length (WEMl) and time (WEMt), deflection amplitude 2 mm ratio max, deflection amplitude max, stiffness parameter, and biomechanically corrected IOP were measured in 39 patients with thyroid orbitopathy (= group I) and in 33 age- and gender-matched healthy subjects (= group II) using the CST. Results : Mean age in group I was 54.3 ± 11.6 years and in group II 54.2 ± 12.3 years with no statistical significant difference between the groups ( P = 0.98). The gender distribution between the groups was not statistically significantly different ( P = 0.51). Mean central corneal thickness was 571 ± 30 µm in group I and 563 ± 36 µm in group II ( P = 0.306). There were statistically significant differences ( P < 0.001) between groups I and II in mean IOP (19.3 ± 4.5 vs. 14.8 ± 2.3 mmHg, mean biomechanically corrected IOP (17.1 ± 3.4 vs. 13.4 ± 2.1 mmHg), mean WEMl (207 ± 57 vs. 322 ± 50 µm), mean WEMt (20.5 ± 1.0 vs. 21.9 ± 0.7 ms), mean IOP-adjusted WEMl (213 ± 56 vs. 314 ± 62 µm), and in mean stiffness parameter (132.5 ± 29.6 vs. 107.8 ± 23.3 mmHg/mm), respectively. Conclusion : Biomechanical parameters as measured by the CST were significantly reduced in patients with thyroid orbitopathy compared to age- and gender-matched healthy subjects, indicating a reduction in orbital compliance in thyroid orbitopathy. The parameters WEMl and WEMt might be a useful diagnostic tool to evaluate the condition of the eyeball within the orbit. … (more)
- Is Part Of:
- Current eye research. Volume 43:Number 3(2018)
- Journal:
- Current eye research
- Issue:
- Volume 43:Number 3(2018)
- Issue Display:
- Volume 43, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 43
- Issue:
- 3
- Issue Sort Value:
- 2018-0043-0003-0000
- Page Start:
- 289
- Page End:
- 292
- Publication Date:
- 2018-03-04
- Subjects:
- Dynamic Scheimpflug Analyzer -- Corvis-ST -- thyroid orbitopathy -- biomechanics -- whole eye movement
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02713683.2017.1405044 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5790.xml