Bacterial pathogens were detected from human exhaled breath using a novel protocol. (March 2018)
- Record Type:
- Journal Article
- Title:
- Bacterial pathogens were detected from human exhaled breath using a novel protocol. (March 2018)
- Main Title:
- Bacterial pathogens were detected from human exhaled breath using a novel protocol
- Authors:
- Zheng, Yunhao
Chen, Haoxuan
Yao, Maosheng
Li, Xiaoguang - Abstract:
- Abstract: It is generally believed that influenza outbreak is associated with breath-borne transmission of viruses, however relevant evidence is little for that of respiratory bacterial infections. On another front, point-of-care infection diagnostic methods at the bedside are significantly lacking. Here, we used a newly developed protocol of integrating an exhaled breath condensate (EBC) collection device (PKU BioScreen) and Loop Mediated Isothermal Amplification (LAMP) to investigate what bacterial pathogens can be directly exhaled out from humans. Exhaled breath condensates were collected from human subjects with respiratory infection symptoms at Peking University 3rd hospital using the BioScreen. The screened bacterial pathogens included Streptococcus pneumoniae, Staphylococcus aureus, Methicillin-resistant Stphylococcus aureus (MRSA), Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia, Haemophilus influenzae, Legionella pneumophila, Mycoplasma Pneumonia, Chlamydia pneumonia, and Mycobacterium tuberculosis. The results were further compared and validated using throat swabs from the same patients by a PCR method. Here, human bacterial pathogens such as H. influenzae, P. aeruginosa, E. coli, S. aureus and MRSA were detected in exhaled breath using the developed protocol that integrates the EBC collection and LAMP. For the patients recruited from the hospital, seven types of pathogens were detected fromAbstract: It is generally believed that influenza outbreak is associated with breath-borne transmission of viruses, however relevant evidence is little for that of respiratory bacterial infections. On another front, point-of-care infection diagnostic methods at the bedside are significantly lacking. Here, we used a newly developed protocol of integrating an exhaled breath condensate (EBC) collection device (PKU BioScreen) and Loop Mediated Isothermal Amplification (LAMP) to investigate what bacterial pathogens can be directly exhaled out from humans. Exhaled breath condensates were collected from human subjects with respiratory infection symptoms at Peking University 3rd hospital using the BioScreen. The screened bacterial pathogens included Streptococcus pneumoniae, Staphylococcus aureus, Methicillin-resistant Stphylococcus aureus (MRSA), Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia, Haemophilus influenzae, Legionella pneumophila, Mycoplasma Pneumonia, Chlamydia pneumonia, and Mycobacterium tuberculosis. The results were further compared and validated using throat swabs from the same patients by a PCR method. Here, human bacterial pathogens such as H. influenzae, P. aeruginosa, E. coli, S. aureus and MRSA were detected in exhaled breath using the developed protocol that integrates the EBC collection and LAMP. For the patients recruited from the hospital, seven types of pathogens were detected from 36.5% of them, and for the remaining subjects none of those screened bacterial pathogens was detected. Importantly, some super resistant bacteria such as MRSA were detected from the exhaled breath, suggesting that breathing might be also an important bacterial transmission route. Results from throat swabs showed that 36.2% of the subjects were found to be infected with H. influenzae, P. aeruginosa, E. coli, S. maltophilia, S. aureus and MRSA. For the EBC samples, 33.3% were found to be infected with MRSA, E. coli and P. aeruginosa . Depending on the initial pathogen load in the sample, the entire protocol (EBC-LAMP) only takes 20–60 min to complete for a respiratory infection diagnosis. For different detection methods and pathogens, the agreements between the EBC and throat swabs from the same patients were found to range from 35% to 65%. Here, we have detected several bacterial pathogens including MRSA from exhaled breath, and the developed protocol could be very useful for the bedside pathogen screening particularly in remote areas where resources are significantly limited or prohibited. Highlights: Many bacterial pathogens including Hemophilus Influenzae and MRSA can be emitted via breathing. The BioScreen device together with LAMP can efficiently screen pathogens from exhaled breath. The leading bacterial infection is H. Influenzae and using WBC could lead to wrong respiratory diagnosis. … (more)
- Is Part Of:
- Journal of aerosol science. Volume 117(2018)
- Journal:
- Journal of aerosol science
- Issue:
- Volume 117(2018)
- Issue Display:
- Volume 117, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 117
- Issue:
- 2018
- Issue Sort Value:
- 2018-0117-2018-0000
- Page Start:
- 224
- Page End:
- 234
- Publication Date:
- 2018-03
- Subjects:
- Airborne transmission -- Pathogens -- Exhaled breath condensate -- Throat swabs -- LAMP
Aerosols -- Periodicals
Aerosols -- Periodicals
Aérosols -- Périodiques
541.34515 - Journal URLs:
- http://www.journals.elsevier.com/journal-of-aerosol-science/ ↗
http://www.sciencedirect.com/science/journal/00218502 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jaerosci.2017.12.009 ↗
- Languages:
- English
- ISSNs:
- 0021-8502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4919.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5764.xml