Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. (January 2018)
- Record Type:
- Journal Article
- Title:
- Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. (January 2018)
- Main Title:
- Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae
- Authors:
- Scheele, C.
Pietschmann, M.F.
Schröder, C.
Grupp, T.
Holderied, M.
Jansson, V.
Müller, P.E. - Abstract:
- Abstract: Background: Unicompartmental knee arthoplasty is a well-established treatment modality for anteromedial osteoarthritis and can be implanted minimally-invasive. However, the operation is technically demanding, which might lead to an increased failure rate. This study was conducted to determine the influence of a minimally-invasive approach on biomechanical fixation strength and morphological cement penetration. Methods: Tibial unicompartmental knee arthroplasties were implanted in 8 cadaver knees. On the medial side, implantation was performed minimally-invasive (group A). The lateral side was operated in an open way (group B). Biomechanical stability was testes using dynamic compression-shear load to failure. Cement penetration was analyzed on serial cuts through the implant–cement–bone interface in the frontal plane. Findings: Mean load to failure was 2438 N (SD 968 N) in group A and 2231 N (SD 1044 N) in group B ( P = 1.0). The area proportion of the cement–bone interface without cement penetration was 24.2% (SD 18.8%) in group A and 7.7% (SD 5.9%) in group B ( P < 0.05). In group A, cement mantle increased in thickness from 0.21 mm (SD 0.18 mm) in the anterior section of the tibial head to 1.35 mm (SD 0.33 mm) in its posterior section ( P < 0.0001). Interpretation: The study demonstrates no inferiority of minimally-invasive surgery with respect to fixation strength. However, the higher area proportion of the cement–bone interface without penetration and theAbstract: Background: Unicompartmental knee arthoplasty is a well-established treatment modality for anteromedial osteoarthritis and can be implanted minimally-invasive. However, the operation is technically demanding, which might lead to an increased failure rate. This study was conducted to determine the influence of a minimally-invasive approach on biomechanical fixation strength and morphological cement penetration. Methods: Tibial unicompartmental knee arthroplasties were implanted in 8 cadaver knees. On the medial side, implantation was performed minimally-invasive (group A). The lateral side was operated in an open way (group B). Biomechanical stability was testes using dynamic compression-shear load to failure. Cement penetration was analyzed on serial cuts through the implant–cement–bone interface in the frontal plane. Findings: Mean load to failure was 2438 N (SD 968 N) in group A and 2231 N (SD 1044 N) in group B ( P = 1.0). The area proportion of the cement–bone interface without cement penetration was 24.2% (SD 18.8%) in group A and 7.7% (SD 5.9%) in group B ( P < 0.05). In group A, cement mantle increased in thickness from 0.21 mm (SD 0.18 mm) in the anterior section of the tibial head to 1.35 mm (SD 0.33 mm) in its posterior section ( P < 0.0001). Interpretation: The study demonstrates no inferiority of minimally-invasive surgery with respect to fixation strength. However, the higher area proportion of the cement–bone interface without penetration and the increasing thickness of cement mantle from anterior to posterior indicate further room for improvement of the minimally-invasive approach in unicompartmental knee arthroplasty. Highlights: Impact of minimally-invasive approach in tibial unicompartmental knee arthroplasty No significant impact of minimally-invasive technique on biomechanical stability Minimally-invasive technique reduces area-wide bone-cement-interdigitation. Minimally-invasive technique leads to an increasing thickness of the cement mantle. Evenly-distributed penetration remains challenging via minimally-invasive approach. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 51(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 51(2018)
- Issue Display:
- Volume 51, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 51
- Issue:
- 2018
- Issue Sort Value:
- 2018-0051-2018-0000
- Page Start:
- 34
- Page End:
- 39
- Publication Date:
- 2018-01
- Subjects:
- Minimally-invasive surgery -- Cement penetration -- Primary stability -- Pulsed lavage -- Unicompartmental knee arthroplasty
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2017.11.006 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5744.xml