Evaluation of interference fit and bone damage of an uncemented femoral knee implant. (January 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of interference fit and bone damage of an uncemented femoral knee implant. (January 2018)
- Main Title:
- Evaluation of interference fit and bone damage of an uncemented femoral knee implant
- Authors:
- Berahmani, Sanaz
Hendriks, Maartje
de Jong, Joost J.A.
van den Bergh, Joop P.W.
Maal, Thomas
Janssen, Dennis
Verdonschot, Nico - Abstract:
- Abstract: Background: During implantation of an uncemented femoral knee implant, press-fit interference fit provides the primary stability. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much press-fit interference fit is eventually achieved. Methods: Five cadaveric femora were prepared and implantation was performed by an experienced surgeon. Micro-CT- and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. Additionally, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions. By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. Findings: Our analysis showed an average cutting error of 0.67 mm (SD 0.17 mm), which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48 mm (SD 0.27 mm), which was close to the nominal value of 1.5 mm. Interpretation: We observed combinations of bone damage and elastic deformation in all bone specimens, which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation. The results of the current study indicateAbstract: Background: During implantation of an uncemented femoral knee implant, press-fit interference fit provides the primary stability. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much press-fit interference fit is eventually achieved. Methods: Five cadaveric femora were prepared and implantation was performed by an experienced surgeon. Micro-CT- and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. Additionally, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions. By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. Findings: Our analysis showed an average cutting error of 0.67 mm (SD 0.17 mm), which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48 mm (SD 0.27 mm), which was close to the nominal value of 1.5 mm. Interpretation: We observed combinations of bone damage and elastic deformation in all bone specimens, which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation. The results of the current study indicate different factors that interact while implanting an uncemented femoral knee component. This knowledge can be used to fine-tune design criteria of femoral components to achieve adequate primary stability for all patients. Highlights: Interference fit and bone damage was assessed using micro-CT scan of distal femurs. Average actual interference fit was close to the nominal interference fit. It was revealed that damage goes beyond the bone-implant interface. Bone density was the most effective factor to achieve high interference fit. Bone particles can penetrate into the inter-trabecular spaces. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 51(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 51(2018)
- Issue Display:
- Volume 51, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 51
- Issue:
- 2018
- Issue Sort Value:
- 2018-0051-2018-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2018-01
- Subjects:
- Uncemented total knee replacement -- Bone damage -- Micro-CT scan -- Bone density -- Press-fit interference fit
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2017.10.022 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5744.xml