A method of detecting the cracks of concrete undergo high-temperature. (20th February 2018)
- Record Type:
- Journal Article
- Title:
- A method of detecting the cracks of concrete undergo high-temperature. (20th February 2018)
- Main Title:
- A method of detecting the cracks of concrete undergo high-temperature
- Authors:
- Li, Lang
Wang, Qingyuan
Zhang, Guomin
Shi, Long
Dong, Jiangfeng
Jia, Pu - Abstract:
- Highlights: Local binarization and extraction were used to detect the cracks. The binarization of a local area is based on the intensity of the local area. The method performs well in detecting the cracks in the cross-sections. No additional process was needed before the images were taken. Geometric attributes are acquired during the detection process. Abstract: Cracking of concrete is one of the critical parameters for the structural safety evaluation of building components after high-temperature exposure. In this paper, a method was developed to detect the cracks of concrete after exposure to high temperature. The gray-scale images of the cross-sections of concrete were binarized with a local-binarization algorithm, and then the isolate cracks were extracted to analyze the geometric attributes, including length, average width, and area. The factor of circle of each isolate crack was used to filter the noise and fake cracks. The proposed method was applied to the real images of both cross-sections and surfaces of high-temperature-damaged concrete to test the effectiveness. Moreover, based on the detection results, the effects of four parameters, i.e. local window size ( Sw ), step size ( Sstep ), local threshold ratio ( Rt ) and upper limit of factor of circle ( Fc, lmt ), in the proposed method were discussed to decide the optimal option. The results indicate that with the optimal parameters ( Sw = 10 pixels, Sstep = 0.5, Rt = 0.85 for cross-sections and 0.95 forHighlights: Local binarization and extraction were used to detect the cracks. The binarization of a local area is based on the intensity of the local area. The method performs well in detecting the cracks in the cross-sections. No additional process was needed before the images were taken. Geometric attributes are acquired during the detection process. Abstract: Cracking of concrete is one of the critical parameters for the structural safety evaluation of building components after high-temperature exposure. In this paper, a method was developed to detect the cracks of concrete after exposure to high temperature. The gray-scale images of the cross-sections of concrete were binarized with a local-binarization algorithm, and then the isolate cracks were extracted to analyze the geometric attributes, including length, average width, and area. The factor of circle of each isolate crack was used to filter the noise and fake cracks. The proposed method was applied to the real images of both cross-sections and surfaces of high-temperature-damaged concrete to test the effectiveness. Moreover, based on the detection results, the effects of four parameters, i.e. local window size ( Sw ), step size ( Sstep ), local threshold ratio ( Rt ) and upper limit of factor of circle ( Fc, lmt ), in the proposed method were discussed to decide the optimal option. The results indicate that with the optimal parameters ( Sw = 10 pixels, Sstep = 0.5, Rt = 0.85 for cross-sections and 0.95 for surface, Fc, lmt = 0.3), the proposed method can detect the cracks on both the surface and cross-section of concrete effectively. Some unclear cracks which were not detected with the optimal parameters can be detected out by combining the results from different groups of parameters. … (more)
- Is Part Of:
- Construction & building materials. Volume 162(2018)
- Journal:
- Construction & building materials
- Issue:
- Volume 162(2018)
- Issue Display:
- Volume 162, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 162
- Issue:
- 2018
- Issue Sort Value:
- 2018-0162-2018-0000
- Page Start:
- 345
- Page End:
- 358
- Publication Date:
- 2018-02-20
- Subjects:
- Crack detection -- Local binarization -- High-temperature-damaged concrete -- Cross-section
Building materials -- Periodicals
624.18 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09500618 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.conbuildmat.2017.12.010 ↗
- Languages:
- English
- ISSNs:
- 0950-0618
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3420.950900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: