Motivations for a Custom Apparatus for Sonophoresis Experimentation. Issue 20 (2015)
- Record Type:
- Journal Article
- Title:
- Motivations for a Custom Apparatus for Sonophoresis Experimentation. Issue 20 (2015)
- Main Title:
- Motivations for a Custom Apparatus for Sonophoresis Experimentation
- Authors:
- Robertson, J.
Becker, S - Abstract:
- Abstract: This paper discusses the motivations and initial design specifications relating to a custom experimental apparatus for sonophoresis experimentation. Sonophoresis experiments usually involve inserting a cylindrical transducer into a glass Franz diffusion cell. The motivations for a custom apparatus are: the hypothesis that the pressure amplitude that is applied to the current system by the transducer is not equal to the pressure amplitude at a point on the skin surface due to acoustic reflections in the system (this is supported by preliminary qualitative results from a numerical model under development); the ultrasound induced heating within Franz diffusion cells that often requires researchers to change experimental fluids mid experiment; and the high standard deviations in published results. Some proposed design specifications are: to maximize the uniformity of the ultrasound field; to allow for the control of temperature in all mediums present; to allow for independent variable values at the skin surface to be measured or accurately estimated; to maximize the accuracy of the measured dependent variable/s; to minimize the effects of any extraneous variables; and to minimize standard deviation between repetitions (maximize repeatability). Numerical modelling and 3D printing are both expected to be vital to the development of this apparatus. This proposed apparatus is intended to improve the validity and repeatability of in vitro sonophoresis experiments.
- Is Part Of:
- IFAC-PapersOnLine. Volume 48:Issue 20(2015)
- Journal:
- IFAC-PapersOnLine
- Issue:
- Volume 48:Issue 20(2015)
- Issue Display:
- Volume 48, Issue 20 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue:
- 20
- Issue Sort Value:
- 2015-0048-0020-0000
- Page Start:
- 100
- Page End:
- 105
- Publication Date:
- 2015
- Subjects:
- transdermal -- sonophoresis -- diffusion -- experimentation -- ultrasound -- 3D printing
Automatic control -- Periodicals
629.805 - Journal URLs:
- https://www.journals.elsevier.com/ifac-papersonline/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ifacol.2015.10.122 ↗
- Languages:
- English
- ISSNs:
- 2405-8963
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5707.xml