Bra band size measurements derived from three-dimensional scans are not accurate in women with large, ptotic breasts. Issue 3 (4th March 2018)
- Record Type:
- Journal Article
- Title:
- Bra band size measurements derived from three-dimensional scans are not accurate in women with large, ptotic breasts. Issue 3 (4th March 2018)
- Main Title:
- Bra band size measurements derived from three-dimensional scans are not accurate in women with large, ptotic breasts
- Authors:
- McGhee, Deirdre E.
Ramsay, Lauren G.
Coltman, Celeste E.
Gho, Sheridan A.
Steele, Julie R. - Abstract:
- Abstract: This study investigated differences in standard measurements used to determine bra size, under-bust chest circumference (UBCC) and over-bust chest circumference (OBCC), measured from a three-dimensional scan (hand-held scanner) compared to the direct measurement in 111 women (age 21–56 years; right breast volume 57–1672 mL; bra size 10A–18G). Bland–Altman plots of UBCC measurements showed a large positive bias and wide limits of agreement (12 cm; −4.6 to 28 cm), which increased as band size increased but decreased when the breasts were digitally removed from the scan prior to the UBCC measurement. The difference in UBCC measurements determined from scans compared to direct measurement had a strong positive correlation with breast volume and breast ptotis. The OBCC measurements showed a small positive bias (2.4 cm; −3.4 to 8.4), consistent across the range of bra sizes. Bra band size measurements determined from three-dimensional scans can be inaccurate in women with large, ptotic breasts. Practitioner Summary: We investigated potential errors in anthropometric data derived from three-dimensional scans used for bra design and fit. Bra band size measurements taken from three-dimensional scans were over-estimated in women with large breasts, whereas bra cup size measurements were accurate to within one-cup size across the entire range of bra sizes.
- Is Part Of:
- Ergonomics. Volume 61:Issue 3(2018)
- Journal:
- Ergonomics
- Issue:
- Volume 61:Issue 3(2018)
- Issue Display:
- Volume 61, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 61
- Issue:
- 3
- Issue Sort Value:
- 2018-0061-0003-0000
- Page Start:
- 464
- Page End:
- 472
- Publication Date:
- 2018-03-04
- Subjects:
- Anthropometry -- bra size -- three-dimensional scanning -- breast -- bra design
Human engineering -- Periodicals
Cybernetics -- Periodicals
Industrial management -- Periodicals
Ergonomie -- Périodiques
Cybernétique -- Périodiques
Gestion d'entreprise -- Périodiques
620.8205 - Journal URLs:
- http://www.tandfonline.com/toc/terg20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00140139.2017.1349936 ↗
- Languages:
- English
- ISSNs:
- 0014-0139
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3808.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5704.xml