Combination of a subcutaneous ICD in a patient with a baroreceptor activation device: Feasibility, safety, and precautions: A Case Report. Issue 12 (12th July 2017)
- Record Type:
- Journal Article
- Title:
- Combination of a subcutaneous ICD in a patient with a baroreceptor activation device: Feasibility, safety, and precautions: A Case Report. Issue 12 (12th July 2017)
- Main Title:
- Combination of a subcutaneous ICD in a patient with a baroreceptor activation device: Feasibility, safety, and precautions: A Case Report
- Authors:
- Kuffer, Liz
Steven, Daniel
Halbach, Marcel
Lüker, Jakob
van den Bruck, Jan‐Hendrik
Sultan, Arian - Abstract:
- Abstract: We present a case of a patient with a baroreflex activation therapy (BAT) receiving a subcutaneous implantable cardioverter defibrillator (S‐ICD). We anticipated two possible hazardous interactions between the two devices. Stimulation by the BAT could be adjudicated as noise and result in underdetection of ventricular arrhythmias or it might be misinterpreted as ventricular arrhythmias and lead to inappropriate shocks. Postop ensing occurred, the upper limit of pulse width of the BAT was limited because of noise detection by the S‐ICD, but the upper limit of amplitude was limited by patient's discomfort. In this patient, the combination of a BAT and an S‐ICD was safe.
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 40:Issue 12(2017)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 40:Issue 12(2017)
- Issue Display:
- Volume 40, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 40
- Issue:
- 12
- Issue Sort Value:
- 2017-0040-0012-0000
- Page Start:
- 1486
- Page End:
- 1488
- Publication Date:
- 2017-07-12
- Subjects:
- baroreceptor activation therapy -- device interaction -- heart failure -- primary prevention of sudden cardiac death -- subcutaneous ICD
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13109 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5689.xml