Quantification of the area and shunt volume of multiple, circular, and noncircular ventricular septal defects: A 2D/3D echocardiography comparison and real time 3D color Doppler feasibility determination study. Issue 1 (29th October 2017)
- Record Type:
- Journal Article
- Title:
- Quantification of the area and shunt volume of multiple, circular, and noncircular ventricular septal defects: A 2D/3D echocardiography comparison and real time 3D color Doppler feasibility determination study. Issue 1 (29th October 2017)
- Main Title:
- Quantification of the area and shunt volume of multiple, circular, and noncircular ventricular septal defects: A 2D/3D echocardiography comparison and real time 3D color Doppler feasibility determination study
- Authors:
- Tracy, Evan
Zhu, Meihua
Streiff, Cole
Sahn, David J.
Ashraf, Muhammad - Abstract:
- Abstract : Background: Quantification of defect size and shunt flow is an important aspect of ventricular septal defect (VSD) evaluation. This study compared three‐dimensional echocardiography (3DE) with the current clinical standard two‐dimensional echocardiography (2DE) for quantifying defect area and tested the feasibility of real time 3D color Doppler echocardiography (RT3D‐CDE) for quantifying shunt volume of irregular shaped and multiple VSDs. Methods: Latex balloons were sutured into the ventricles of 32 freshly harvested porcine hearts and were connected with tubing placed in septal perforations. Tubing was varied in area (0.13–5.22 cm²), number (1–3), and shape (circle, oval, crescent, triangle). A pulsatile pump was used to pump "blood" through the VSD (LV to RV) at stroke volumes of 30–70 mL with a stroke rate of 60 bpm. Two‐dimensional echocardiography (2DE), 3DE, and RT3D‐CDE images were acquired from the right side of the phantom. Results: For circular VSDs, both 2DE and 3DE area measurements were consistent with the actual areas ( R ² = 0.98 vs 0.99). For noncircular/multiple VSDs, 3DE correlated with the actual area more closely than 2DE ( R ² = 0.99 vs 0.44). Shunt volumes obtained using RT3D‐CDE positively correlated with pumped stroke volumes ( R ² = 0.96). Conclusions: Three‐dimensional echocardiography (3DE) is a feasible method for determining VSD area and is more accurate than 2DE for evaluating the area of multiple or noncircular VSDs. Real‐time 3DAbstract : Background: Quantification of defect size and shunt flow is an important aspect of ventricular septal defect (VSD) evaluation. This study compared three‐dimensional echocardiography (3DE) with the current clinical standard two‐dimensional echocardiography (2DE) for quantifying defect area and tested the feasibility of real time 3D color Doppler echocardiography (RT3D‐CDE) for quantifying shunt volume of irregular shaped and multiple VSDs. Methods: Latex balloons were sutured into the ventricles of 32 freshly harvested porcine hearts and were connected with tubing placed in septal perforations. Tubing was varied in area (0.13–5.22 cm²), number (1–3), and shape (circle, oval, crescent, triangle). A pulsatile pump was used to pump "blood" through the VSD (LV to RV) at stroke volumes of 30–70 mL with a stroke rate of 60 bpm. Two‐dimensional echocardiography (2DE), 3DE, and RT3D‐CDE images were acquired from the right side of the phantom. Results: For circular VSDs, both 2DE and 3DE area measurements were consistent with the actual areas ( R ² = 0.98 vs 0.99). For noncircular/multiple VSDs, 3DE correlated with the actual area more closely than 2DE ( R ² = 0.99 vs 0.44). Shunt volumes obtained using RT3D‐CDE positively correlated with pumped stroke volumes ( R ² = 0.96). Conclusions: Three‐dimensional echocardiography (3DE) is a feasible method for determining VSD area and is more accurate than 2DE for evaluating the area of multiple or noncircular VSDs. Real‐time 3D color Doppler echocardiography (RT3D‐CDE) is a feasible method for quantifying the shunt volume of multiple or noncircular VSDs. … (more)
- Is Part Of:
- Echocardiography. Volume 35:Issue 1(2018)
- Journal:
- Echocardiography
- Issue:
- Volume 35:Issue 1(2018)
- Issue Display:
- Volume 35, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 35
- Issue:
- 1
- Issue Sort Value:
- 2018-0035-0001-0000
- Page Start:
- 90
- Page End:
- 99
- Publication Date:
- 2017-10-29
- Subjects:
- color Doppler three‐dimensional -- echocardiography -- perimembranous ventricular septal defect -- shunt -- three‐dimensional echocardiography
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.13742 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5690.xml