A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate. (7th December 2017)
- Record Type:
- Journal Article
- Title:
- A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate. (7th December 2017)
- Main Title:
- A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate
- Authors:
- Wang, Jiazheng
Wright, Alan J.
Hesketh, Richard L.
Hu, De‐en
Brindle, Kevin M. - Abstract:
- Abstract : Single‐shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C‐labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In a dynamic acquisition of a series of images, this results in the sacrifice of a time point if the reference scan involves a full readout train with no phase encoding. This time penalty is negligible if an integrated navigator echo is used, but at the cost of a lower signal‐to‐noise ratio (SNR) as a result of prolonged T 2 * decay. We describe here a workflow for hyperpolarized 13 C EPI that requires no reference scan. This involves the selection of a ghost‐containing background from a 13 C image of a single metabolite at a single time point, the identification of phase correction coefficients that minimize signal in the selected area, and the application of these coefficients to images acquired at all time points and from all metabolites. The workflow was compared in phantom experiments with phase correction using a 13 C reference scan, and yielded similar results in situations with a regular field of view (FOV), a restricted FOV and where there were multiple signal sources. When compared with alternative phase correction methods, the workflow showed an SNR benefit relativeAbstract : Single‐shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C‐labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In a dynamic acquisition of a series of images, this results in the sacrifice of a time point if the reference scan involves a full readout train with no phase encoding. This time penalty is negligible if an integrated navigator echo is used, but at the cost of a lower signal‐to‐noise ratio (SNR) as a result of prolonged T 2 * decay. We describe here a workflow for hyperpolarized 13 C EPI that requires no reference scan. This involves the selection of a ghost‐containing background from a 13 C image of a single metabolite at a single time point, the identification of phase correction coefficients that minimize signal in the selected area, and the application of these coefficients to images acquired at all time points and from all metabolites. The workflow was compared in phantom experiments with phase correction using a 13 C reference scan, and yielded similar results in situations with a regular field of view (FOV), a restricted FOV and where there were multiple signal sources. When compared with alternative phase correction methods, the workflow showed an SNR benefit relative to integrated 13 C reference echoes (>15%) or better ghost removal relative to a 1 H reference scan. The residual ghosting in a slightly de‐shimmed B 0 field was 1.6% using the proposed workflow and 3.8% using a 1 H reference scan. The workflow was implemented with a series of dynamically acquired hyperpolarized [1‐ 13 C]pyruvate and [1‐ 13 C]lactate images in vivo, resulting in images with no observable ghosting and which were quantitatively similar to images corrected using a 13 C reference scan. Abstract : We describe a workflow for hyperpolarized 13 C echo planar imaging (EPI) that requires no reference scan. The workflow involves the selection of a ghost‐containing background from a 13 C image of a single metabolite at a single time point, search for phase correction coefficients that minimize signal in the selected area, and application of these coefficients to images acquired at all time points and from all metabolites. The workflow shows benefits in terms of the acquisition of fewer data, higher signal‐to‐noise ratio (SNR) and better ghost removal when compared with alternative methods. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 31:Number 2(2018)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 31:Number 2(2018)
- Issue Display:
- Volume 31, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2018-0031-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-12-07
- Subjects:
- [1‐13C]lactate -- [1‐13C]pyruvate -- EPI -- ghosting -- hyperpolarized -- imaging -- metabolism -- tumours
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3866 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5678.xml