A national survey of MRI safety practices in Ghana. Issue 12 (December 2017)
- Record Type:
- Journal Article
- Title:
- A national survey of MRI safety practices in Ghana. Issue 12 (December 2017)
- Main Title:
- A national survey of MRI safety practices in Ghana
- Authors:
- Piersson, Albert Dayor
Gorleku, Philip Nii - Abstract:
- Abstract: Objective: The aim of the present study was to assess current MRI safety practices among MRI facilities in Ghana, and their compliance with the 2013 American College of Radiology (ACR) guidance document on MR safe practices. Material and methods: A questionnaire developed from the 2013 ACR Guidance Document was used to collect information on magnetic field strengths, MR safety policy and compliance, patient screening, emergency preparedness, infection control, MRI safety accessories, equipment safety, signage and barriers, report of adverse incidents, and access and communication. Results: Out of the 13 MRI facilities identified, response rate of 92% was obtained. Six (50%) facilities indicated they have MRI safety policy and have it present and readily available to facility staff. Five (42%) facilities indicated they have handheld magnets, and 1(8%) has ferromagnetic detection system. Only one (8%) had crash carts. Seven (58%) facilities have zone 4 clearly marked with a red light and lighted sign stating "The Magnet is On". One (8%) recorded projectile incident and fire outbreak. Eight (67%) facilities have direct visual observation of access corridors to zone IV. Conclusion: There was compliance in some areas of MRI safety practice, however there were some shortfalls which need to be addressed. We therefore recommend improvement in the following areas: (1) establishment, implementation, and maintenance of current MRI safety policy, (2) patient screening, (3)Abstract: Objective: The aim of the present study was to assess current MRI safety practices among MRI facilities in Ghana, and their compliance with the 2013 American College of Radiology (ACR) guidance document on MR safe practices. Material and methods: A questionnaire developed from the 2013 ACR Guidance Document was used to collect information on magnetic field strengths, MR safety policy and compliance, patient screening, emergency preparedness, infection control, MRI safety accessories, equipment safety, signage and barriers, report of adverse incidents, and access and communication. Results: Out of the 13 MRI facilities identified, response rate of 92% was obtained. Six (50%) facilities indicated they have MRI safety policy and have it present and readily available to facility staff. Five (42%) facilities indicated they have handheld magnets, and 1(8%) has ferromagnetic detection system. Only one (8%) had crash carts. Seven (58%) facilities have zone 4 clearly marked with a red light and lighted sign stating "The Magnet is On". One (8%) recorded projectile incident and fire outbreak. Eight (67%) facilities have direct visual observation of access corridors to zone IV. Conclusion: There was compliance in some areas of MRI safety practice, however there were some shortfalls which need to be addressed. We therefore recommend improvement in the following areas: (1) establishment, implementation, and maintenance of current MRI safety policy, (2) patient screening, (3) provision of training and routine drills on emergency response protocols with documentations, (4) emergency preparedness, and (5) provision of colour codes for equipment used within MRI environment. … (more)
- Is Part Of:
- Heliyon. Volume 3:Issue 12(2017)
- Journal:
- Heliyon
- Issue:
- Volume 3:Issue 12(2017)
- Issue Display:
- Volume 3, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 3
- Issue:
- 12
- Issue Sort Value:
- 2017-0003-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- Health profession -- Health sciences -- Medical imaging
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2017.e00480 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5680.xml