Determination of Cadmium in Human Serum and Blood Samples after Dispersive Liquid–Liquid Microextraction Using a Task-Specific Ionic Liquid. (24th March 2018)
- Record Type:
- Journal Article
- Title:
- Determination of Cadmium in Human Serum and Blood Samples after Dispersive Liquid–Liquid Microextraction Using a Task-Specific Ionic Liquid. (24th March 2018)
- Main Title:
- Determination of Cadmium in Human Serum and Blood Samples after Dispersive Liquid–Liquid Microextraction Using a Task-Specific Ionic Liquid
- Authors:
- Khan, Noman
Kazi, Tasneem Gul
Afridi, Hasan Imran
Arain, Muhammad Balal - Abstract:
- ABSTRACT: Task-specific ionic liquid dispersive liquid–liquid microextraction (TSIL-DLLME) is a simple and rapid preconcentration approach for the measurement of cadmium in serum and blood samples of human subjects. In this method a novel task-specific ionic liquid, trioctylmethyl ammonium thiosalicylate (TOMATS), which has dual characteristics as a chelating agent and extractive solvent, was investigated. TOMATS complexes with Cd due to the chelating effect of the ortho -positioned carboxylate relative to the thiol functionality. The assessment of the optimum values of variables including the pH, amount of reagents (TOMATS, diluents, Triton X114, and back extracting acid solution), temperature, and incubation time, which affect the recoveries of analyte by TSIL-DLLME method were studied. After enrichment experiments, acidic solution was used to back extract the metal ions from the ionic liquid rich phase and with determination by electrothermal atomic absorption spectrometry. Using the optimal experimental conditions, the limit of detection (3 s), precision (relative standard deviation), preconcentration, and enhancement factors of developed method for Cd were found to be 0.05 µg/L, greater than 5%, 62.5, and 52.8, respectively. To check the accuracy of the developed method, certified reference material of serum and blood were analyzed by the developed method, and the measured values of Cd were in good agreement with the certified values. The developed method was appliedABSTRACT: Task-specific ionic liquid dispersive liquid–liquid microextraction (TSIL-DLLME) is a simple and rapid preconcentration approach for the measurement of cadmium in serum and blood samples of human subjects. In this method a novel task-specific ionic liquid, trioctylmethyl ammonium thiosalicylate (TOMATS), which has dual characteristics as a chelating agent and extractive solvent, was investigated. TOMATS complexes with Cd due to the chelating effect of the ortho -positioned carboxylate relative to the thiol functionality. The assessment of the optimum values of variables including the pH, amount of reagents (TOMATS, diluents, Triton X114, and back extracting acid solution), temperature, and incubation time, which affect the recoveries of analyte by TSIL-DLLME method were studied. After enrichment experiments, acidic solution was used to back extract the metal ions from the ionic liquid rich phase and with determination by electrothermal atomic absorption spectrometry. Using the optimal experimental conditions, the limit of detection (3 s), precision (relative standard deviation), preconcentration, and enhancement factors of developed method for Cd were found to be 0.05 µg/L, greater than 5%, 62.5, and 52.8, respectively. To check the accuracy of the developed method, certified reference material of serum and blood were analyzed by the developed method, and the measured values of Cd were in good agreement with the certified values. The developed method was applied successfully to determine Cd in blood and serum samples of lymphatic cancer patients relative to healthy controls. … (more)
- Is Part Of:
- Analytical letters. Volume 51:Number 5(2018)
- Journal:
- Analytical letters
- Issue:
- Volume 51:Number 5(2018)
- Issue Display:
- Volume 51, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 51
- Issue:
- 5
- Issue Sort Value:
- 2018-0051-0005-0000
- Page Start:
- 673
- Page End:
- 685
- Publication Date:
- 2018-03-24
- Subjects:
- Biological samples -- blood lymphoma -- cadmium -- dispersive liquid–liquid microextraction -- electrothermal atomic absorption spectrometry -- trioctylmethyl ammonium thiosalicylate
Chemistry, Analytic -- Periodicals
Chemistry, Analytic -- Abstracts
543 - Journal URLs:
- http://www.tandfonline.com/toc/lanl20/current ↗
http://taylorandfrancis.metapress.com/link.asp?id=107818, ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00032719.2017.1354868 ↗
- Languages:
- English
- ISSNs:
- 0003-2719
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5670.xml