Comparing hepatic 2D and 3D magnetic resonance elastography methods in a clinical setting – Initial experiences. (2015)
- Record Type:
- Journal Article
- Title:
- Comparing hepatic 2D and 3D magnetic resonance elastography methods in a clinical setting – Initial experiences. (2015)
- Main Title:
- Comparing hepatic 2D and 3D magnetic resonance elastography methods in a clinical setting – Initial experiences
- Authors:
- Forsgren, Mikael F.
Norén, Bengt
Kihlberg, Johan
Dahlqvist Leinhard, Olof
Kechagias, Stergios
Lundberg, Peter - Abstract:
- Abstract: Purpose: Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and ' G abs, Elastic ') MRE are comparable. Materials and methods: Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. Results: Stiffness correlated well with the elasticity, R 2 = 0.96 ( P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with ' G abs, Elastic ' R 2 = 0.96 ( P < 0.001; slope = 0.95, intercept = 0.28 kPa). Conclusion: This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of suchAbstract: Purpose: Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and ' G abs, Elastic ') MRE are comparable. Materials and methods: Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. Results: Stiffness correlated well with the elasticity, R 2 = 0.96 ( P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with ' G abs, Elastic ' R 2 = 0.96 ( P < 0.001; slope = 0.95, intercept = 0.28 kPa). Conclusion: This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression. … (more)
- Is Part Of:
- European journal of radiology open. Volume 2(2015)
- Journal:
- European journal of radiology open
- Issue:
- Volume 2(2015)
- Issue Display:
- Volume 2, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 2
- Issue:
- 2015
- Issue Sort Value:
- 2015-0002-2015-0000
- Page Start:
- 66
- Page End:
- 70
- Publication Date:
- 2015
- Subjects:
- Liver -- Rheology -- Elastography -- Fibrosis -- MRE -- MRI
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2015.04.001 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5660.xml