IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T. (2015)
- Record Type:
- Journal Article
- Title:
- IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T. (2015)
- Main Title:
- IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T
- Authors:
- Cui, Yong
Dyvorne, Hadrien
Besa, Cecilia
Cooper, Nancy
Taouli, Bachir - Abstract:
- Abstract: Purpose: To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods: In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm 2 . A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b 0, 200, 400 and 800 s/mm 2 . Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results: The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values ( p = 0.006–0.020), except for b 0 ( p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T ( p = 0.005–0.044), except for ADC ( p = 0.748). The inter-platform reproducibility of true diffusion coefficient ( D ) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient ( D *) showed more limited inter-platform reproducibility (mean CV of 22.6% forAbstract: Purpose: To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods: In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm 2 . A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b 0, 200, 400 and 800 s/mm 2 . Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results: The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values ( p = 0.006–0.020), except for b 0 ( p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T ( p = 0.005–0.044), except for ADC ( p = 0.748). The inter-platform reproducibility of true diffusion coefficient ( D ) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient ( D *) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D *). Conclusion: Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D * parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. … (more)
- Is Part Of:
- European journal of radiology open. Volume 2(2015)
- Journal:
- European journal of radiology open
- Issue:
- Volume 2(2015)
- Issue Display:
- Volume 2, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 2
- Issue:
- 2015
- Issue Sort Value:
- 2015-0002-2015-0000
- Page Start:
- 123
- Page End:
- 128
- Publication Date:
- 2015
- Subjects:
- ADC apparent diffusion coefficient -- D true diffusion coefficient -- D* pseudo diffusion coefficient -- DWI diffusion-weighted imaging -- IVIM intravoxel incoherent motion
Diffusion-weighted imaging -- Intravoxel incoherent motion -- 3.0 T -- Liver -- Reproducibility
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2015.08.001 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5660.xml