Inducing targeted failure in cadaveric testing of 3-segment spinal units with and without simulated metastases. (January 2018)
- Record Type:
- Journal Article
- Title:
- Inducing targeted failure in cadaveric testing of 3-segment spinal units with and without simulated metastases. (January 2018)
- Main Title:
- Inducing targeted failure in cadaveric testing of 3-segment spinal units with and without simulated metastases
- Authors:
- Groenen, Karlijn H.J.
Janssen, Dennis
van der Linden, Yvette M.
Kooloos, Jan G.M.
Homminga, Jasper
Verdonschot, Nico
Tanck, Esther - Abstract:
- Highlights: A method to induce targeted failure in 3-segment spinal units is proposed. A method to capture specimens' deformation in the post-failure state is proposed. An adequate failure criterion is important in testing 3-segment spinal units. Abstract: We propose an experimental setup and protocol able to induce targeted failure of the middle vertebra in 3-segment spinal units and to capture the specimens' deformation in their post-failure state. Sixteen 3-segment spinal units with and without artificial metastases were destructively tested in axial compression using one of two failure criteria; either: (A) A clear drop in force (>10–15% of peak force) (n = 4); or (B) A minimum displacement of 5 mm (n = 12). Subsequently, the specimens were fully fixated in polymethylmethacrylate (PMMA), thereby preserving their post-failure state. Pre- and post-experiment computed tomography (CT) scans were acquired to determine the occurrence of failure in one of the vertebral bodies. All specimens were successfully fixated in their post-failure state. When applying failure criterion A, two specimens showed signs of failure. When applying failure criterion B, all specimens showed signs of failure; in 9 out of 12 specimens this occurred in the middle vertebrae only. In conclusion, this research provides an experimental setup and protocol able to induce targeted failure of 3-segment spinal units and to capture the specimens' deformation in their post-failure state. Furthermore, thisHighlights: A method to induce targeted failure in 3-segment spinal units is proposed. A method to capture specimens' deformation in the post-failure state is proposed. An adequate failure criterion is important in testing 3-segment spinal units. Abstract: We propose an experimental setup and protocol able to induce targeted failure of the middle vertebra in 3-segment spinal units and to capture the specimens' deformation in their post-failure state. Sixteen 3-segment spinal units with and without artificial metastases were destructively tested in axial compression using one of two failure criteria; either: (A) A clear drop in force (>10–15% of peak force) (n = 4); or (B) A minimum displacement of 5 mm (n = 12). Subsequently, the specimens were fully fixated in polymethylmethacrylate (PMMA), thereby preserving their post-failure state. Pre- and post-experiment computed tomography (CT) scans were acquired to determine the occurrence of failure in one of the vertebral bodies. All specimens were successfully fixated in their post-failure state. When applying failure criterion A, two specimens showed signs of failure. When applying failure criterion B, all specimens showed signs of failure; in 9 out of 12 specimens this occurred in the middle vertebrae only. In conclusion, this research provides an experimental setup and protocol able to induce targeted failure of 3-segment spinal units and to capture the specimens' deformation in their post-failure state. Furthermore, this study illustrates the importance of an adequate failure criterion for successful simulation of vertebral fractures in an experimental setup. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 51(2018)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 51(2018)
- Issue Display:
- Volume 51, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 51
- Issue:
- 2018
- Issue Sort Value:
- 2018-0051-2018-0000
- Page Start:
- 104
- Page End:
- 110
- Publication Date:
- 2018-01
- Subjects:
- Spine -- Vertebral strength -- Mechanical testing -- Fracture -- Deformation -- Failure criterion -- Metastases
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2017.11.007 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5647.xml