A single ended directional fault section identifier and fault locator for double circuit transmission lines using combined wavelet and ANN approach. (July 2015)
- Record Type:
- Journal Article
- Title:
- A single ended directional fault section identifier and fault locator for double circuit transmission lines using combined wavelet and ANN approach. (July 2015)
- Main Title:
- A single ended directional fault section identifier and fault locator for double circuit transmission lines using combined wavelet and ANN approach
- Authors:
- Yadav, Anamika
Swetapadma, Aleena - Abstract:
- Highlights: Wavelet and ANN based approach is used for fault section identification and location. The average % error in fault location is within 0.001% which is lesser as compared to other techniques. The proposed scheme offers primary protection to 99% of line length. It also offers backup protection to 99% of the adjacent forward and reverse line sections. Abstract: Fault section identification and determining its location are important aspects to reduce down/repair time, speed up restoration of power supply and to improve the reliability. In this paper combined wavelet and artificial neural network based directional protection scheme is proposed for double circuit transmission lines using single end data to identify the faulty section and its location with reach setting up to 99% of line length. The proposed method requires the three phase currents and voltage to be measured at one end of the double circuit transmission line modelled using distributed parameter line model which also considers the effect of shunt capacitance. Approximate coefficients feature vector of the three phase voltage and current are extracted using discrete wavelet transform to train the ANN with Levenberg Marquardt algorithm. The proposed scheme involves two stages. The first stage identifies the zone/section of the fault and the second stage calculates the fault location from the relaying point. The proposed combined Wavelet and ANN based fault location scheme is also compared with ANFIS basedHighlights: Wavelet and ANN based approach is used for fault section identification and location. The average % error in fault location is within 0.001% which is lesser as compared to other techniques. The proposed scheme offers primary protection to 99% of line length. It also offers backup protection to 99% of the adjacent forward and reverse line sections. Abstract: Fault section identification and determining its location are important aspects to reduce down/repair time, speed up restoration of power supply and to improve the reliability. In this paper combined wavelet and artificial neural network based directional protection scheme is proposed for double circuit transmission lines using single end data to identify the faulty section and its location with reach setting up to 99% of line length. The proposed method requires the three phase currents and voltage to be measured at one end of the double circuit transmission line modelled using distributed parameter line model which also considers the effect of shunt capacitance. Approximate coefficients feature vector of the three phase voltage and current are extracted using discrete wavelet transform to train the ANN with Levenberg Marquardt algorithm. The proposed scheme involves two stages. The first stage identifies the zone/section of the fault and the second stage calculates the fault location from the relaying point. The proposed combined Wavelet and ANN based fault location scheme is also compared with ANFIS based fault location scheme. The test results of the proposed scheme show that the fault section identification and location estimation is very accurate and the average percentage error in fault location estimation is within 0.001%. This method is adaptive to the variation of fault type (both forward and reverse), fault inception angle, fault location and fault resistance. The main advantage of the proposed scheme is that it offers primary protection to 99% of line length using single end data only and also backup protection to the adjacent forward and reverse line sections. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 69(2015:Jul.)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 69(2015:Jul.)
- Issue Display:
- Volume 69 (2015)
- Year:
- 2015
- Volume:
- 69
- Issue Sort Value:
- 2015-0069-0000-0000
- Page Start:
- 27
- Page End:
- 33
- Publication Date:
- 2015-07
- Subjects:
- Discrete wavelet transform -- Directional relaying -- Reach setting -- ANN -- Fault section identification -- Fault location
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2014.12.079 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5645.xml