Incorporation of Silicon Carbide and Diamond‐Like Carbon as Adhesion Promoters Improves In Vitro and In Vivo Stability of Thin‐Film Glassy Carbon Electrocorticography Arrays. Issue 1 (17th November 2017)
- Record Type:
- Journal Article
- Title:
- Incorporation of Silicon Carbide and Diamond‐Like Carbon as Adhesion Promoters Improves In Vitro and In Vivo Stability of Thin‐Film Glassy Carbon Electrocorticography Arrays. Issue 1 (17th November 2017)
- Main Title:
- Incorporation of Silicon Carbide and Diamond‐Like Carbon as Adhesion Promoters Improves In Vitro and In Vivo Stability of Thin‐Film Glassy Carbon Electrocorticography Arrays
- Authors:
- Vomero, Maria
Castagnola, Elisa
Ordonez, Juan S.
Carli, Stefano
Zucchini, Elena
Maggiolini, Emma
Gueli, Calogero
Goshi, Noah
Ciarpella, Francesca
Cea, Claudia
Fadiga, Luciano
Ricci, Davide
Kassegne, Sam
Stieglitz, Thomas - Abstract:
- Abstract: Thin‐film neural devices are an appealing alternative to traditional implants, although their chronic stability remains matter of investigation. In this study, a chronically stable class of thin‐film devices for electrocorticography is manufactured incorporating silicon carbide and diamond‐like carbon as adhesion promoters between glassy carbon (GC) electrodes and polyimide and between GC and platinum traces. The devices are aged in three solutions—phosphate‐buffered saline (PBS), 30 × 10 −3 and 150 × 10 −3 m H2 O2 /PBS—and stressed using cyclic voltammetry (2500 cycles) and 20 million biphasic pulses. Electrochemical impedance spectroscopy (EIS) and image analysis are performed to detect eventual changes of the electrodes morphology. Results demonstrate that the devices are able to undergo chemically induced oxidative stress and electrical stimulation without failing but actually improving their electrical performance until a steady state is reached. Additionally, cell viability tests are carried out to verify the noncytotoxicity of the materials, before chronically implanting them into rat models. The behavior of the GC electrodes in vivo is monitored through EIS and sensorimotor evoked potential recordings which confirm that, with GC being activated, impedance lowers and quality of recorded signal improves. Histological analysis of the brain tissue is performed and shows no sign of severe immune reaction to the implant. Abstract : The incorporation of siliconAbstract: Thin‐film neural devices are an appealing alternative to traditional implants, although their chronic stability remains matter of investigation. In this study, a chronically stable class of thin‐film devices for electrocorticography is manufactured incorporating silicon carbide and diamond‐like carbon as adhesion promoters between glassy carbon (GC) electrodes and polyimide and between GC and platinum traces. The devices are aged in three solutions—phosphate‐buffered saline (PBS), 30 × 10 −3 and 150 × 10 −3 m H2 O2 /PBS—and stressed using cyclic voltammetry (2500 cycles) and 20 million biphasic pulses. Electrochemical impedance spectroscopy (EIS) and image analysis are performed to detect eventual changes of the electrodes morphology. Results demonstrate that the devices are able to undergo chemically induced oxidative stress and electrical stimulation without failing but actually improving their electrical performance until a steady state is reached. Additionally, cell viability tests are carried out to verify the noncytotoxicity of the materials, before chronically implanting them into rat models. The behavior of the GC electrodes in vivo is monitored through EIS and sensorimotor evoked potential recordings which confirm that, with GC being activated, impedance lowers and quality of recorded signal improves. Histological analysis of the brain tissue is performed and shows no sign of severe immune reaction to the implant. Abstract : The incorporation of silicon carbide and diamond‐like carbon as adhesion promoters between glassy carbon (GC) electrodes and polyimide and between GC and platinum traces greatly improves in vitro and in vivo stability of GC electrocorticography (ECoG) arrays. The devices undergo chemically induced oxidative stress and electrical stimulation without delaminating and failing. After chronic implants, no sign of severe immune reaction is shown. … (more)
- Is Part Of:
- Advanced biosystems. Volume 2 :Issue 1 (2018)
- Journal:
- Advanced biosystems
- Issue:
- Volume 2 :Issue 1 (2018)
- Issue Display:
- Volume 2, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2018-0002-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-11-17
- Subjects:
- adhesion promoters -- chronic stability -- glassy carbon -- interfaces -- electrocorticography arrays
Biological systems -- Periodicals
Biotechnology -- Periodicals
Bioengineering -- Periodicals
Biomedical engineering -- Periodicals
Biological Science Disciplines
Periodicals
Periodicals
660.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2366-7478 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adbi.201700081 ↗
- Languages:
- English
- ISSNs:
- 2366-7478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.830500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5645.xml