Two‐site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid. (3rd September 2017)
- Record Type:
- Journal Article
- Title:
- Two‐site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid. (3rd September 2017)
- Main Title:
- Two‐site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid
- Authors:
- Buoro, S.
Peruzzi, B.
Fanelli, A.
Seghezzi, M.
Manenti, B.
Lorubbio, M.
Biagioli, T.
Nannini, S.
Ottomano, C.
Lippi, G. - Abstract:
- Abstract: Introduction: Cellular analysis in cerebrospinal fluid (CSF) provides important diagnostic information in many pathological settings. The aim of this two‐site study was to evaluate the Sysmex XN Body Fluid mode (XN‐BF) for cell analysis of CSF compared to light microscopy (LM). Methods: Two hundred and seven consecutive CSF samples were analyzed in parallel with XN‐BF and LM. The study also included the estimation of the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), carry‐over and linearity of XN‐BF module. Results: LoQ of white blood cells (WBC) was 3×10 6 cells/L; linearity was good and carry‐over negligible. XN‐BF parameters were compared to LM for the following cell classes: total cells, WBC, polymorphonuclear (PMN), and mononuclear (MN) cells. The bias ranged from 1.3 to 15.2×10 6 cells/L. The receiver operating characteristics curve analysis for WBC showed an area under the curve of 0.98, and the global diagnostic agreement was 95% at a cutoff of 5×10 6 cells/L. Conclusions: XN‐BF provides rapid and accurate counts in clinically relevant ranges of CSF values, thus providing a valuable alternative to conventional LM analysis. However, microscopic review remains advisable in samples with abnormal cell counts or high fluorescent (HF‐BF) cell parameter exceeding 5×10 6 cells/L.
- Is Part Of:
- International journal of laboratory hematology. Volume 40:Number 1(2018:Feb.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 40:Number 1(2018:Feb.)
- Issue Display:
- Volume 40, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2018-0040-0001-0000
- Page Start:
- 26
- Page End:
- 33
- Publication Date:
- 2017-09-03
- Subjects:
- automated cell count -- body fluid -- cerebrospinal fluid -- Sysmex -- XN
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12723 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5643.xml