Reproducibility of inspiratory muscle endurance testing using PowerBreathe for COPD patients. (10th April 2017)
- Record Type:
- Journal Article
- Title:
- Reproducibility of inspiratory muscle endurance testing using PowerBreathe for COPD patients. (10th April 2017)
- Main Title:
- Reproducibility of inspiratory muscle endurance testing using PowerBreathe for COPD patients
- Authors:
- Basso‐Vanelli, Renata P.
Di Lorenzo, Valéria A.P.
Ramalho, Mariane
Labadessa, Ivana G.
Regueiro, Eloisa M.G.
Jamami, Mauricio
Costa, Dirceu - Abstract:
- Abstract: Background: Assessing the strength and endurance of respiratory muscles is fundamental for characterizing respiratory muscle dysfunction. Although a variety of tests are used to evaluate respiratory muscle endurance, not all of them are applicable in clinical practice. Assessments can be made using a practical device called PowerBreathe®, but its reproducibility has not been tested in chronic obstructive pulmonary disease (COPD) patients. Aim: To verify the reproducibility of the inspiratory muscle endurance test using a manometer and PowerBreathe® in COPD patients. Methods: A cross‐sectional study was used. In total, 19 moderate–severe COPD patients, male and female, aged 50 to 80 years took part in the research. This evaluation consisted of 2 tests: an incremental test and a constant one held on the same day and repeated after 48 hr. The incremental test started with 10‐cm H2 O, adding 10‐cm H2 O every 2 min and taking 1 min of rest before increasing the load. The highest load that could be sustained for at least 1 min was considered the sustained maximum inspiratory pressure (SMIP) value. The constant test was performed at an intensity of 80% of the SMIP and the maximum time limit was 30 min. Results: In the incremental test, there was a significant increase in the SMIP compared to the test–retest (61 ± 24/64.7 ± 23.8; p = .015); the value of the relative reproducibility was 0.96, the standard error of the absolute measurement was 4.7 (95% confidence intervalAbstract: Background: Assessing the strength and endurance of respiratory muscles is fundamental for characterizing respiratory muscle dysfunction. Although a variety of tests are used to evaluate respiratory muscle endurance, not all of them are applicable in clinical practice. Assessments can be made using a practical device called PowerBreathe®, but its reproducibility has not been tested in chronic obstructive pulmonary disease (COPD) patients. Aim: To verify the reproducibility of the inspiratory muscle endurance test using a manometer and PowerBreathe® in COPD patients. Methods: A cross‐sectional study was used. In total, 19 moderate–severe COPD patients, male and female, aged 50 to 80 years took part in the research. This evaluation consisted of 2 tests: an incremental test and a constant one held on the same day and repeated after 48 hr. The incremental test started with 10‐cm H2 O, adding 10‐cm H2 O every 2 min and taking 1 min of rest before increasing the load. The highest load that could be sustained for at least 1 min was considered the sustained maximum inspiratory pressure (SMIP) value. The constant test was performed at an intensity of 80% of the SMIP and the maximum time limit was 30 min. Results: In the incremental test, there was a significant increase in the SMIP compared to the test–retest (61 ± 24/64.7 ± 23.8; p = .015); the value of the relative reproducibility was 0.96, the standard error of the absolute measurement was 4.7 (95% confidence interval 9.2), and the minimum detectable difference was 10.9. In the Bland–Altman analysis, the mean error was 4.2 (confidence interval −7.6 to 16.1). The constant test was not reproducible. Conclusion: It was observed that the incremental test was reproducible to evaluate inspiratory muscle endurance in COPD patients. Furthermore, 2 tests needed to be carried out due to the learning effect. … (more)
- Is Part Of:
- Physiotherapy research international. Volume 23:Number 1(2018)
- Journal:
- Physiotherapy research international
- Issue:
- Volume 23:Number 1(2018)
- Issue Display:
- Volume 23, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 23
- Issue:
- 1
- Issue Sort Value:
- 2018-0023-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-04-10
- Subjects:
- COPD -- muscle endurance test -- respiratory muscles -- test–retest reproducibility
Physical therapy -- Periodicals
Physical Therapy Modalities -- Periodicals
Physiothérapie -- Périodiques
615.82 - Journal URLs:
- http://eproxy.lib.hku.hk/login?url=http://search.epnet.com/direct.asp?db=aph&jn="GPG"&scope=site ↗
http://www.pri-online.org/ ↗
http://onlinelibrary.wiley.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1471-2865 ↗ - DOI:
- 10.1002/pri.1687 ↗
- Languages:
- English
- ISSNs:
- 1358-2267
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.119000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5639.xml