Safety and function of a prototype microprocessor-controlled knee prosthesis for low active transfemoral amputees switching from a mechanic knee prosthesis: a pilot study. (17th February 2018)
- Record Type:
- Journal Article
- Title:
- Safety and function of a prototype microprocessor-controlled knee prosthesis for low active transfemoral amputees switching from a mechanic knee prosthesis: a pilot study. (17th February 2018)
- Main Title:
- Safety and function of a prototype microprocessor-controlled knee prosthesis for low active transfemoral amputees switching from a mechanic knee prosthesis: a pilot study
- Authors:
- Hasenoehrl, Timothy
Schmalz, Thomas
Windhager, Reinhard
Domayer, Stephan
Dana, Sara
Ambrozy, Clemens
Palma, Stefano
Crevenna, Richard - Abstract:
- Abstract: Purpose: Aim of this pilot study was to assess safety and functioning of a microprocessor-controlled knee prosthesis (MPK) after a short familiarization time and no structured physical therapy. Materials and methods: Five elderly, low-active transfemoral amputees who were fitted with a standard non-microprocessor controlled knee prosthesis (NMPK) performed a baseline measurement consisting of a 3 D gait analysis, functional tests and questionnaires. The first follow-up consisted of the same test procedure and was performed with the MPK after 4 to 6 weeks of familiarization. After being refitted to their standard NMPK again, the subjects undertook the second follow-up which consisted of solely questionnaires 4 weeks later. Results: Questionnaires and functional tests showed an increase in the perception of safety. Moreover, gait analysis revealed more physiologic knee and hip extension/flexion patterns when using the MPK. Conclusion: Our results showed that although the Genium with Cenior-Leg ruleset-MPK (GCL-MPK) might help to improve several safety-related outcomes as well as gait biomechanics the functional potential of the GCL-MPK may have been limited without specific training and a sufficient acclimation period. Implications for Rehabilitation: Elderly transfemoral amputees are often limited in their activity by safety issues as well as insufficient functioning regarding the non microprocessor-controlled knee prostheses (NMPK), thing that could be eliminatedAbstract: Purpose: Aim of this pilot study was to assess safety and functioning of a microprocessor-controlled knee prosthesis (MPK) after a short familiarization time and no structured physical therapy. Materials and methods: Five elderly, low-active transfemoral amputees who were fitted with a standard non-microprocessor controlled knee prosthesis (NMPK) performed a baseline measurement consisting of a 3 D gait analysis, functional tests and questionnaires. The first follow-up consisted of the same test procedure and was performed with the MPK after 4 to 6 weeks of familiarization. After being refitted to their standard NMPK again, the subjects undertook the second follow-up which consisted of solely questionnaires 4 weeks later. Results: Questionnaires and functional tests showed an increase in the perception of safety. Moreover, gait analysis revealed more physiologic knee and hip extension/flexion patterns when using the MPK. Conclusion: Our results showed that although the Genium with Cenior-Leg ruleset-MPK (GCL-MPK) might help to improve several safety-related outcomes as well as gait biomechanics the functional potential of the GCL-MPK may have been limited without specific training and a sufficient acclimation period. Implications for Rehabilitation: Elderly transfemoral amputees are often limited in their activity by safety issues as well as insufficient functioning regarding the non microprocessor-controlled knee prostheses (NMPK), thing that could be eliminated with the use of suitable microprocessor-controlled prostheses (MPK). The safety and functioning of a prototype MPK (GCL-MPK) specifically designed for the needs of older and low-active transfemoral amputees was assessed in this pilot study. The GCL-MPK showed indicators of increased safety and more natural walking patterns in older and low-active transfemoral amputees in comparison to the standard NMPK already after a short acclimatisation time and no structured physical therapy. Regarding functional performance it seems as if providing older and low-active transfemoral amputees with the GCL-MPK alone without prescribing structured prosthesis training might be insufficient to achieve improvements over the standard NMPKs. … (more)
- Is Part Of:
- Disability and rehabilitation. Volume 13:Number 2(2018)
- Journal:
- Disability and rehabilitation
- Issue:
- Volume 13:Number 2(2018)
- Issue Display:
- Volume 13, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 13
- Issue:
- 2
- Issue Sort Value:
- 2018-0013-0002-0000
- Page Start:
- 157
- Page End:
- 165
- Publication Date:
- 2018-02-17
- Subjects:
- Microprocessor-controlled knee prosthesis -- mechanic knee prosthesis -- transfemoral amputees -- K2 ambulators -- gait analysis
Rehabilitation technology -- Periodicals
Self-help devices for people with disabilities -- Periodicals
617.03 - Journal URLs:
- http://informahealthcare.com/journal/idt ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/17483107.asp ↗ - DOI:
- 10.1080/17483107.2017.1300344 ↗
- Languages:
- English
- ISSNs:
- 1748-3107
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3595.420350
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5628.xml