Assessment of corrosion in retrieved spine implants. Issue 2 (9th March 2017)
- Record Type:
- Journal Article
- Title:
- Assessment of corrosion in retrieved spine implants. Issue 2 (9th March 2017)
- Main Title:
- Assessment of corrosion in retrieved spine implants
- Authors:
- Panagiotopoulou, V. C.
Hothi, H. S.
Anwar, H. A.
Molloy, S.
Noordeen, H.
Rezajooi, K.
Sutcliffe, J.
Skinner, J. A.
Hart, A. J. - Abstract:
- ABSTRACT: Recently the use of dissimilar metals in spine instrumentation has increased, especially in the case of adult deformities, where rods made from Cobalt Chrome alloys (CoCr) are used with Titanium (Ti) screws. The use of dissimilar metals increases the risk of galvanic corrosion and patients have required revision spine surgery due to severe metallosis that may have been caused by corrosion. We aimed to assess the presence of corrosion in spine implant retrievals from constructs with two types of material combinations: similar (Ti/Ti) and dissimilar (CoCr/Ti). First, we devised a grading score for corrosion of the rod‐fixture junctions. Then, we applied this score to a collection of retrieved spine implants. Our proposed corrosion grading score was proven reliable (kappa > 0.7). We found no significant difference in the scores between 4 CoCr and 11 Ti rods ( p = 0.0642). There was no indication that time of implantation had an effect on the corrosion score ( p = 0.9361). We recommend surgeons avoid using implants designs with dissimilar metals to reduce the risk of corrosion whilst a larger scale study of retrieved spine implants is conducted. Future studies can now use our scoring system for spine implant corrosion. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 632–638, 2018.
- Is Part Of:
- Journal of biomedical materials research. Volume 106:Issue 2(2018)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 106:Issue 2(2018)
- Issue Display:
- Volume 106, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 106
- Issue:
- 2
- Issue Sort Value:
- 2018-0106-0002-0000
- Page Start:
- 632
- Page End:
- 638
- Publication Date:
- 2017-03-09
- Subjects:
- corrosion -- spinal implant -- cobalt–chromium (alloys) -- titanium (alloys) -- implant retrieval
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.33858 ↗
- Languages:
- English
- ISSNs:
- 1552-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.725000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5602.xml