Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping. Issue 2 (20th April 2017)
- Record Type:
- Journal Article
- Title:
- Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping. Issue 2 (20th April 2017)
- Main Title:
- Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping
- Authors:
- Lankford, Christopher L.
Does, Mark D. - Abstract:
- Abstract : Purpose: Quantitative MRI may require correcting for nuisance parameters which can or must be constrained to independently measured or assumed values. The noise and/or bias in these constraints propagate to fitted parameters. For example, the case of refocusing pulse flip angle constraint in multiple spin echo T 2 mapping is explored. Methods: An analytical expression for the mean‐squared error of a parameter of interest was derived as a function of the accuracy and precision of an independent estimate of a nuisance parameter. The expression was validated by simulations and then used to evaluate the effects of flip angle (θ) constraint on the accuracy and precision of T ⁁ 2 for a variety of multi‐echo T 2 mapping protocols. Results: Constraining θ improved T ⁁ 2 precision when the θ‐map signal‐to‐noise ratio was greater than approximately one‐half that of the first spin echo image. For many practical scenarios, constrained fitting was calculated to reduce not just the variance but the full mean‐squared error of T ⁁ 2, for bias in θ ⁁ ≲ 6 % . Conclusion: The analytical expression derived in this work can be applied to inform experimental design in quantitative MRI. The example application to T 2 mapping provided specific cases, depending on θ ⁁ accuracy and precision, in which θ ⁁ measurement and constraint would be beneficial to T ⁁ 2 variance or mean‐squared error. Magn Reson Med 79:673–682, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 2(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 2(2018)
- Issue Display:
- Volume 79, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 2
- Issue Sort Value:
- 2018-0079-0002-0000
- Page Start:
- 673
- Page End:
- 682
- Publication Date:
- 2017-04-20
- Subjects:
- MRI -- precision -- accuracy: T2 -- B1
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26713 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5600.xml