Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator. (December 2017)
- Record Type:
- Journal Article
- Title:
- Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator. (December 2017)
- Main Title:
- Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator
- Authors:
- Veselsky, T.
Novotny, J.
Pastykova, V.
Koniarova, I. - Abstract:
- Highlights: Contradictions about MicroDiamond correction factors have been presented so far. MicroDiamond correction factors for CyberKnife are mostly within 1%. MicroDiamond correction factors for LGK Perfexion are within 2%. MicroDiamond correction factors for linear accelerator are mostly within 0.5%. MicroDiamond was found to be almost ideal tool for relative small field dosimetry. Abstract: Purpose: The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Materials and methods: Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin / M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin, Qmsr fclin, fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. Results: PTW microDiamond correction factors for CyberKnife field sizes 25–5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTWHighlights: Contradictions about MicroDiamond correction factors have been presented so far. MicroDiamond correction factors for CyberKnife are mostly within 1%. MicroDiamond correction factors for LGK Perfexion are within 2%. MicroDiamond correction factors for linear accelerator are mostly within 0.5%. MicroDiamond was found to be almost ideal tool for relative small field dosimetry. Abstract: Purpose: The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Materials and methods: Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin / M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin, Qmsr fclin, fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. Results: PTW microDiamond correction factors for CyberKnife field sizes 25–5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTW microDiamond M Qclin fclin / M Qmsr fmsr for the linear accelerator varied from MC corrected Dosimetry Diode data by less than 0.5% (except for 1 × 1 cm 2 field size with 1.3% deviation). Conclusions: Regarding low resulting correction factor values, the PTW microDiamond detector may be considered an almost ideal tool for relative small field dosimetry in a large variety of stereotactic and radiosurgery treatment devices. … (more)
- Is Part Of:
- Physica medica. Volume 44(2018)
- Journal:
- Physica medica
- Issue:
- Volume 44(2018)
- Issue Display:
- Volume 44, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 2018
- Issue Sort Value:
- 2018-0044-2018-0000
- Page Start:
- 66
- Page End:
- 71
- Publication Date:
- 2017-12
- Subjects:
- Small field dosimetry -- Synthetic diamond detector -- Output factor -- Correction factor
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.11.010 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5571.xml