40. Validation of a transit EPID device for a clinical use: application to iViewDose (Elekta). (December 2017)
- Record Type:
- Journal Article
- Title:
- 40. Validation of a transit EPID device for a clinical use: application to iViewDose (Elekta). (December 2017)
- Main Title:
- 40. Validation of a transit EPID device for a clinical use: application to iViewDose (Elekta)
- Authors:
- Delaby, N.
Bouvier, J.
Jouyaux, F.
Barateau, A.
Lafond, C. - Abstract:
- Abstract : Introduction: IMRT/VMAT and stereotactic treatments require patient specific quality assurance before and during treatment. In that context, Electronic Portal Imaging Device (EPID) can be used for pre-treatment and in vivo verification. The aim of this study was to evaluate a new in vivo portal dosimetry tool iViewDose (Elekta) for a clinical use. Methods: The study was performed on a VersaHD LINAC equipped with Agility collimator and EPID iView v.3.4.1 (Elekta). iViewDose v.1.0.1 (Elekta) software allows users to reconstruct delivered dose by the LINAC in 3D on the planning CT scan using EPID images. Treatment plans were calculated with Pinnacle v.9.10 (Philips) for VMAT technique. Agreement between calculation and measurement was evaluated with gamma index analysis in 3D ( γ 3D, criteria: 3% global/3 mm, threshold 50%). Detector validation was realized in two steps: (i) detector intrinsic characteristics evaluation (repeatability, reproducibility, linearity, dose rate dependence) and (ii) evaluation of error detectability for two treatment plan complexities (prostate and Head & Neck) delivered on an anthropomorphic phantom with: leaves shift from 1 to 5 mm, collimator rotation from 1 to 5° and MU increase from 1% to 5%. The in vivo agreement between calculation and measurement was investigated for nine patients (H&N, liver, esophagus, iliac bone) corresponding in a total of 86 fractions. According to the obtained results, a parallel analysis with CBCT images wasAbstract : Introduction: IMRT/VMAT and stereotactic treatments require patient specific quality assurance before and during treatment. In that context, Electronic Portal Imaging Device (EPID) can be used for pre-treatment and in vivo verification. The aim of this study was to evaluate a new in vivo portal dosimetry tool iViewDose (Elekta) for a clinical use. Methods: The study was performed on a VersaHD LINAC equipped with Agility collimator and EPID iView v.3.4.1 (Elekta). iViewDose v.1.0.1 (Elekta) software allows users to reconstruct delivered dose by the LINAC in 3D on the planning CT scan using EPID images. Treatment plans were calculated with Pinnacle v.9.10 (Philips) for VMAT technique. Agreement between calculation and measurement was evaluated with gamma index analysis in 3D ( γ 3D, criteria: 3% global/3 mm, threshold 50%). Detector validation was realized in two steps: (i) detector intrinsic characteristics evaluation (repeatability, reproducibility, linearity, dose rate dependence) and (ii) evaluation of error detectability for two treatment plan complexities (prostate and Head & Neck) delivered on an anthropomorphic phantom with: leaves shift from 1 to 5 mm, collimator rotation from 1 to 5° and MU increase from 1% to 5%. The in vivo agreement between calculation and measurement was investigated for nine patients (H&N, liver, esophagus, iliac bone) corresponding in a total of 86 fractions. According to the obtained results, a parallel analysis with CBCT images was carried out. Results: Dose response of the detector was linear (R 2 = 1). A x ¯ / σ of 0.06% was obtained for measurements performed with a dose rate varying from 70 to 500 MU/min. For a same irradiation, reconstructed dose was repeatable ( x ¯ / σ = 0.07%) and reproducible ( x ¯ / σ = 0.2%). For H&N treatment plan, iViewDose could detect a 1 mm bank shift ( γ 3D percentage decreased from 91.7% to 67.6%), a 2° collimator rotation ( γ 3D percentage decreased to 76.8%) and an increase of 1% MU ( γ 3D percentage decreased to 84.6%). A two bank shift in the same direction was not detected. Similar results were obtained for prostate treatment plans. In vivo calculation/measurement coherence for five patients (liver, esophagus, iliac bone) showed on average a γ 3D percentage of 90.9% (30 fractions). Those measurements showed punctually a wrong matching for a liver treatment case near diaphragm (Fig. 1 b). For H&N treatment plans, in vivo calculation/measurement coherence is deteriorated during treatment: 84.4% of points have a gamma <1 in the first fraction. These results decrease to 66.2% for 34 next fractions (mean for four patients). CBCT images analysis highlights several phenomena: shoulder relaxation, anatomical variation near air/tissues interfaces, patient anatomical variations (tumor shrinkage, weight loss) (Fig. 1 a). Conclusions: This study shows the iViewDose capability to detect LINAC and patient potential errors. With that kind of detector, it becomes necessary to correlate those results to a clinical impact and to define action thresholds justifying treatment re-planning. It could be very useful in an adaptive radiotherapy and would be more accurate with dose calculation on CBCT images of the day. … (more)
- Is Part Of:
- Physica medica. Volume 44(2017)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 44(2017)Supplement 1
- Issue Display:
- Volume 44, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2017-0044-0001-0000
- Page Start:
- 19
- Page End:
- 20
- Publication Date:
- 2017-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.10.065 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5569.xml