Dose calculation algorithm accuracy for small fields in non-homogeneous media: The lung SBRT case. (December 2017)
- Record Type:
- Journal Article
- Title:
- Dose calculation algorithm accuracy for small fields in non-homogeneous media: The lung SBRT case. (December 2017)
- Main Title:
- Dose calculation algorithm accuracy for small fields in non-homogeneous media: The lung SBRT case
- Authors:
- Fogliata, Antonella
Cozzi, Luca - Abstract:
- Highlights: The literature regarding the lung SBRT dose calculation algorithm accuracy is reviewed. The small field and low density problems are analysed. A summarizing example focuses on the main differences and aspects of the main three classes of dose calculation algorithms. Abstract: This review addresses the theme of dose calculation accuracy in the case of the stereotactic treatment of lung lesions. Based on the classical categories of type "a", "b" and "c" algorithms (according to their degree of complexity in the management of charged particle transport), a summary of findings from literature is reported. Two main critical areas have been identified: the use of small fields and the presence of low density medium. Concerning the latter point, the algorithm accuracy is intrinsic of the algorithm core, and, notwithstanding the materials discretization and their chemical composition knowledge, type "c" are, at the most, able to reproduce the actual physical dose distribution in heterogeneous media. For what concerns the small field management, the final accuracy could be strongly related to the beam configuration appropriateness in the TPS (as well for MC this relates to the proper linac head description). As a very crude summary, type "a" should be considered as unsuitable for this kind of treatment calculations (with differences of the order of 20–30%), while type "b" and "c" could keep their accuracy approximatively within 10 and 5%, respectively.
- Is Part Of:
- Physica medica. Volume 44(2018)
- Journal:
- Physica medica
- Issue:
- Volume 44(2018)
- Issue Display:
- Volume 44, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 2018
- Issue Sort Value:
- 2018-0044-2018-0000
- Page Start:
- 157
- Page End:
- 162
- Publication Date:
- 2017-12
- Subjects:
- Lung SBRT -- Small fields -- Inhomogeneity -- Low density
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.11.104 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5566.xml