Imaging with ultra-small-angle X-ray scattering using a Laue-case analyzer and its application to human breast tumors. (December 2017)
- Record Type:
- Journal Article
- Title:
- Imaging with ultra-small-angle X-ray scattering using a Laue-case analyzer and its application to human breast tumors. (December 2017)
- Main Title:
- Imaging with ultra-small-angle X-ray scattering using a Laue-case analyzer and its application to human breast tumors
- Authors:
- Shimao, Daisuke
Sunaguchi, Naoki
Sasaya, Tenta
Yuasa, Tetsuya
Ichihara, Shu
Kawasaki, Tomonori
Ando, Masami - Abstract:
- Highlights: We developed USAXS imaging using a Laue-case analyzer. We acquired USAXS images of breast tumor specimens. USAXS imaging can extract closely packed scattering bodies in a specimen. Sensitivity can be controlled by changing the threshold level of the rocking curve. A fusion image is useful for studying USAXS image. Abstract: Purpose: In this study, we demonstrate a novel imaging technique, based on ultra-small-angle X-ray scattering (USAXS) that uses a Laue-case Si wafer as the angle analyzer. Methods: We utilized the (1 1 1) diffraction plane of a 356 μm thick, symmetrically cut Si wafer as the angle analyzer, denoted by A[L]. With this device, we performed USAXS imaging experiments using 19.8 keV synchrotron X-rays. The objects we imaged were formalin-fixed, paraffin-embedded breast tumors (an invasive carcinoma and an intraductal papilloma). During image acquisition by a charge-coupled device (CCD) camera, we varied the rotation angle of the analyzer in 0.02″ steps from −2.40″ to +2.40″ around the Bragg angle. The exposure time for each image was 2 s. We determined the amount of ultra-small-angle X-ray scattering from the width of the intensity curve obtained for each local pixel during the rotation of the analyzer. Results: We acquired USAXS images of malignant and benign breast tumor specimens using the A[L] analyzer; regions with larger USAXS form brighter areas in the image. We varied the sensitivity of the USAXS image by changing the threshold level of theHighlights: We developed USAXS imaging using a Laue-case analyzer. We acquired USAXS images of breast tumor specimens. USAXS imaging can extract closely packed scattering bodies in a specimen. Sensitivity can be controlled by changing the threshold level of the rocking curve. A fusion image is useful for studying USAXS image. Abstract: Purpose: In this study, we demonstrate a novel imaging technique, based on ultra-small-angle X-ray scattering (USAXS) that uses a Laue-case Si wafer as the angle analyzer. Methods: We utilized the (1 1 1) diffraction plane of a 356 μm thick, symmetrically cut Si wafer as the angle analyzer, denoted by A[L]. With this device, we performed USAXS imaging experiments using 19.8 keV synchrotron X-rays. The objects we imaged were formalin-fixed, paraffin-embedded breast tumors (an invasive carcinoma and an intraductal papilloma). During image acquisition by a charge-coupled device (CCD) camera, we varied the rotation angle of the analyzer in 0.02″ steps from −2.40″ to +2.40″ around the Bragg angle. The exposure time for each image was 2 s. We determined the amount of ultra-small-angle X-ray scattering from the width of the intensity curve obtained for each local pixel during the rotation of the analyzer. Results: We acquired USAXS images of malignant and benign breast tumor specimens using the A[L] analyzer; regions with larger USAXS form brighter areas in the image. We varied the sensitivity of the USAXS image by changing the threshold level of the object rocking curve. Conclusions: The USAXS images can provide information about the internal distribution of closely packed scattering bodies in a sample with reasonable sensitivity. This information differs from that obtainable through refraction-contrast imaging. Although further validation studies will be necessary, we conclude that USAXS imaging using a Laue-case analyzer may have significant potential as a new diagnosis technique. … (more)
- Is Part Of:
- Physica medica. Volume 44(2018)
- Journal:
- Physica medica
- Issue:
- Volume 44(2018)
- Issue Display:
- Volume 44, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 2018
- Issue Sort Value:
- 2018-0044-2018-0000
- Page Start:
- 236
- Page End:
- 242
- Publication Date:
- 2017-12
- Subjects:
- Ultra-small-angle X-ray scattering -- Laue-case analyzer -- Breast cancer -- Synchrotron radiation
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.10.018 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5566.xml