Assessment of fiducial markers to enable the co-registration of photographs and MRI data. (March 2015)
- Record Type:
- Journal Article
- Title:
- Assessment of fiducial markers to enable the co-registration of photographs and MRI data. (March 2015)
- Main Title:
- Assessment of fiducial markers to enable the co-registration of photographs and MRI data
- Authors:
- Webb, Bridgette A.
Petrovic, Andreas
Urschler, Martin
Scheurer, Eva - Abstract:
- Abstract: Purpose: To investigate the visualisation of novel external fiducial skin markers in photography and MRI. To co-register photographs and MR images, and additionally assess the spatial accuracy of these co-registrations with the view of future application in the investigation of forensically relevant soft tissue lesions. Methods and materials: Strand-shaped fiducial markers were secured externally over hematomas on the thigh of 10 volunteers. The region of interest was photographed and examined using MRI at 3 T in oblique and transversal orientations and the visibility of the markers assessed. Markers provided 'control points' in both sets of images, enabling the computation of an affine transform to register oblique MR images to photographs. The fiducial registration error was evaluated by calculating the root-mean-square error of nine corresponding evaluation points visible in both modalities. Results: Fiducial markers were clearly visualised in both photography and MRI. The co-registration of photographs and oblique MR images was achieved for all participants. The overall root-mean-square error for registrations was 1.18 mm (TIRM) and 1.46 mm (TSE2D with SPAIR fat-suppression). Conclusions: The proposed approach led to the successful visualisation of non-invasive fiducial markers using photography and MRI (TIRM and TSE2D (SPAIR) sequences). This visualisation, combined with an affine transformation process provided a simple, cost-effective way to accuratelyAbstract: Purpose: To investigate the visualisation of novel external fiducial skin markers in photography and MRI. To co-register photographs and MR images, and additionally assess the spatial accuracy of these co-registrations with the view of future application in the investigation of forensically relevant soft tissue lesions. Methods and materials: Strand-shaped fiducial markers were secured externally over hematomas on the thigh of 10 volunteers. The region of interest was photographed and examined using MRI at 3 T in oblique and transversal orientations and the visibility of the markers assessed. Markers provided 'control points' in both sets of images, enabling the computation of an affine transform to register oblique MR images to photographs. The fiducial registration error was evaluated by calculating the root-mean-square error of nine corresponding evaluation points visible in both modalities. Results: Fiducial markers were clearly visualised in both photography and MRI. The co-registration of photographs and oblique MR images was achieved for all participants. The overall root-mean-square error for registrations was 1.18 mm (TIRM) and 1.46 mm (TSE2D with SPAIR fat-suppression). Conclusions: The proposed approach led to the successful visualisation of non-invasive fiducial markers using photography and MRI (TIRM and TSE2D (SPAIR) sequences). This visualisation, combined with an affine transformation process provided a simple, cost-effective way to accurately co-register photographs and MR images of subcutaneous hematomas located on the thigh. Further investigation of the novel markers and the proposed co-visualisation approach holds potential to improve not only the forensic documentation of soft tissue lesions, but to also improve certain clinical applications, including the area of dermatology. … (more)
- Is Part Of:
- Forensic science international. Volume 248(2015)
- Journal:
- Forensic science international
- Issue:
- Volume 248(2015)
- Issue Display:
- Volume 248, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 248
- Issue:
- 2015
- Issue Sort Value:
- 2015-0248-2015-0000
- Page Start:
- 148
- Page End:
- 153
- Publication Date:
- 2015-03
- Subjects:
- Soft tissue injuries -- MRI -- Fiducial markers -- Forensic medicine -- Multi-modal co-registration
SPAIR spectrally attenuated inversion recovery -- TIRM turbo inversion recovery magnitude -- BI base image -- RMSE root-mean-square error
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2014.12.027 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5568.xml