Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images – Generalized technique for four different MR scanners. Issue 3 (December 2017)
- Record Type:
- Journal Article
- Title:
- Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images – Generalized technique for four different MR scanners. Issue 3 (December 2017)
- Main Title:
- Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images – Generalized technique for four different MR scanners
- Authors:
- Koivula, Lauri
Kapanen, Mika
Seppälä, Tiina
Collan, Juhani
Dowling, Jason A.
Greer, Peter B.
Gustafsson, Christian
Gunnlaugsson, Adalsteinn
Olsson, Lars E.
Wee, Leonard
Korhonen, Juha - Abstract:
- Abstract: Background and purpose: Recent studies have shown that it is possible to conduct entire radiotherapy treatment planning (RTP) workflow using only MR images. This study aims to develop a generalized intensity-based method to generate synthetic CT (sCT) images from standard T2-weighted (T2w ) MR images of the pelvis. Materials and methods: This study developed a generalized dual model HU conversion method to convert standard T2w MR image intensity values to synthetic HU values, separately inside and outside of atlas-segmented bone volume contour. The method was developed and evaluated with 20 and 35 prostate cancer patients, respectively. MR images with scanning sequences in clinical use were acquired with four different MR scanners of three vendors. Results: For the generated synthetic CT (sCT) images of the 35 prostate patients, the mean (and maximal) HU differences in soft and bony tissue volumes were 16 ± 6 HUs (34 HUs) and −46 ± 56 HUs (181 HUs), respectively, against the true CT images. The average of the PTV mean dose difference in sCTs compared to those in true CTs was −0.6 ± 0.4% (−1.3%). Conclusions: The study provides a generalized method for sCT creation from standard T2w images of the pelvis. The method produced clinically acceptable dose calculation results for all the included scanners and MR sequences.
- Is Part Of:
- Radiotherapy and oncology. Volume 125:Issue 3(2017:Dec.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 125:Issue 3(2017:Dec.)
- Issue Display:
- Volume 125, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 125
- Issue:
- 3
- Issue Sort Value:
- 2017-0125-0003-0000
- Page Start:
- 411
- Page End:
- 419
- Publication Date:
- 2017-12
- Subjects:
- MRI-only -- Radiation therapy -- Synthetic CT images
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.10.011 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5563.xml