Ventilation measured on clinical 4D-CBCT: Increased ventilation accuracy through improved image quality. Issue 3 (December 2017)
- Record Type:
- Journal Article
- Title:
- Ventilation measured on clinical 4D-CBCT: Increased ventilation accuracy through improved image quality. Issue 3 (December 2017)
- Main Title:
- Ventilation measured on clinical 4D-CBCT: Increased ventilation accuracy through improved image quality
- Authors:
- Jensen, Kasper R.
Brink, Carsten
Hansen, Olfred
Bernchou, Uffe - Abstract:
- Abstract: Background and purpose: Ventilation measured on 4D cone-beam computed tomography (CBCT) using deformable image registration (DIR) may predict specific radiation sensitivity, but the measurement is affected by the current image quality. With 4D computed tomography (CT) measured ventilation acting as a gold standard the current study investigates if image improvements increase the accuracy of 4D-CBCT measured ventilation. Material and methods: The study consists of 4D-CBCT and 4D-CT scans of 20 non-small-cell lung cancer patients. Raw CBCT projections were subjected to a standard or an improved projection correction and reconstructed by the common FDK-algorithm or the more advanced SART-algorithm. Ventilation was measured as Jacobians calculated from DIR and the comparison between CBCT and CT was done by Spearman correlation. Results: A significant increase in the mean correlation was observed when combining improved projection correction and SART reconstruction (0.34) compared to the clinical standard (0.21). The correlation further increased when averaging ventilation measured from three successive CBCT scans (0.38). Conclusion: The study showed that the combination of improved projection correction and the SART reconstruction increased the accuracy of CBCT ventilation and this result can be a stepping stone to extract dynamic changes in respiration pattern of patients during radiotherapy.
- Is Part Of:
- Radiotherapy and oncology. Volume 125:Issue 3(2017:Dec.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 125:Issue 3(2017:Dec.)
- Issue Display:
- Volume 125, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 125
- Issue:
- 3
- Issue Sort Value:
- 2017-0125-0003-0000
- Page Start:
- 459
- Page End:
- 463
- Publication Date:
- 2017-12
- Subjects:
- Lung cancer -- Functional imaging -- Image improvement -- Ventilation measure
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.10.024 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5563.xml