Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck. Issue 3 (December 2017)
- Record Type:
- Journal Article
- Title:
- Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck. Issue 3 (December 2017)
- Main Title:
- Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck
- Authors:
- Nix, Michael G.
Prestwich, Robin J.D.
Speight, Richard - Abstract:
- Abstract: Background: Head and neck MR-CT deformable image registration (DIR) for radiotherapy planning is hindered by the lack of both ground-truth and per-patient accuracy assessment methods. This study assesses novel post-registration reference-free error assessment algorithms, based on local rigid re-registration of native and pseudomodality images. Methods: Head and neck MR obtained in and out of the treatment position underwent DIR to planning CT. Block-wise mutual information (b-MI) and pseudomodality mutual information (b-pmMI) algorithms were validated against applied rotations and translations. Inherent registration error detection was compared across 14 patient datasets. Results: Using radiotherapy position MR-CT DIR, quantitative comparison of applied rotations and translations revealed that errors between 1 and 4 mm were accurately determined by both algorithms. Using diagnostic position MR-CT DIR, translations of up to 5 mm were accurately detected within the gross tumour volume by both methods. In 14 patient datasets, b-MI and b-pmMI detected similar errors with improved stability in regions of low contrast or CT artefact and a 10-fold speedup for b-pmMI. Conclusions: b-MI and b-pmMI algorithms have been validated as providing accurate reference-free quantitative assessment of DIR accuracy on a per-patient basis. b-pmMI is faster and more robust in the presence of modality-specific information.
- Is Part Of:
- Radiotherapy and oncology. Volume 125:Issue 3(2017:Dec.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 125:Issue 3(2017:Dec.)
- Issue Display:
- Volume 125, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 125
- Issue:
- 3
- Issue Sort Value:
- 2017-0125-0003-0000
- Page Start:
- 478
- Page End:
- 484
- Publication Date:
- 2017-12
- Subjects:
- Deformable image registration -- Multimodal registration -- Contour propagation -- Accuracy assessment -- Head and neck
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.10.004 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5563.xml